Key result
Simulating BiV pacing with a 10% activation onset area most accurately models clinical QRSd shortening.
Why the study?
Clinical response to CRT varies among patients with conduction abnormalities, highlighting the need for more precise patient selection criteria and pacing strategies using computational modeling.
Which activation onset area configuration in biventricular pacing simulation most accurately reflects clinical QRS duration shortening in LBBB patients?
Which activation onset area configuration in biventricular pacing simulation most accurately reflects clinical QRS duration shortening in LBBB patients?
The TAT10 configuration for activation onset area provides the most accurate computational simulation of QRS duration shortening during biventricular pacing in LBBB patients.
Answers are grounded in this paper and cite their sources.
TAT10 refines biventricular pacing simulations in LBBB models; leaves open prospective validation before clinical use.
Cardiac resynchronization therapy (CRT) is a widely used treatment for heart failure patients with conduction abnormalities, particularly left bundle branch block (LBBB). CRT synchronizes ventricular activation, which is usually reflected by a reduction in the duration of the QRS complex (QRSd) observed on the patient’s electrocardiogram (ECG). However, clinical response to CRT varies among patients, highlighting the need for more precise patient selection criteria and pacing strategies. Computational modeling provides a powerful tool for simulating myocardial electrical activation and optimizing CRT protocols on a patient-specific basis.In this study, we employed detailed ventricular models based on data from 55 LBBB patients to simulate biventricular (BiV) pacing using an Eikonal equation. We studied three different configurations for an activation onset area (AOnsA) around the sites of stimulating electrodes in the right and left ventricles during BiV pacing: Spot Activation (SpA), Segment Activation (SegA), and area activated during 10% of the total activation time (TAT10) at SpA. Simulation results calculated under different AOnsA scenarios were compared with clinical data on the QRSd to validate the models.We found that SpA during BiV pacing resulted in an un-realistic increase in QRSd compared to baseline for LBBB activation. Both the SegA and TAT10 configurations produced a reduction in QRSd from baseline. This was qualitatively consistent with clinical observations. The TAT10 method yielded the most accurate simulations of clinical QRSd shortening, with no significant difference compared to patient data.
No takes yet. Share an insight, caveat, or question.
Dzhigil et al. (2025) studied Heart failure with left bundle branch block (LBBB) (n=55). Biventricular pacing simulation using different activation onset areas (SpA, SegA, TAT10) vs. Clinical data on QRS duration / baseline LBBB activation was evaluated on QRS duration (QRSd). Simulating biventricular pacing using an activation onset area of 10% of total activation time (TAT10) yielded the most accurate simulations of clinical QRS duration shortening.
Synapse has enriched 10 related papers. Consider them for comparative context: