Why the study?
Data on the best timing for CRT implantation after achieving stable medical therapy and its association with clinical outcomes were lacking.
Does earlier CRT implantation (<9 months) after achieving stable medical therapy improve cardiovascular outcomes compared to delayed implantation (>9 months) in patients with heart failure?
Does earlier CRT implantation (<9 months) after achieving stable medical therapy improve cardiovascular outcomes compared to delayed implantation (>9 months) in patients with heart failure?
Delayed CRT implantation beyond 3 to 9 months after achieving stable medical therapy is associated with significantly higher risks of cardiovascular mortality and heart failure hospitalization.
Answers are grounded in this paper and cite their sources.
May support earlier CRT after stable therapy in HF; leaves open need for randomized confirmation before practice change.
BACKGROUND: Guidelines' recommendations for cardiac resynchronization therapy (CRT) implantation in selected patients with heart failure (HF) exist. However, data on the best timing for CRT implantation after the achievement of stable medical therapy (SMT) and its association with outcomes are currently lacking. OBJECTIVES: The aim of this study was to investigate the timing of CRT implantation after the achievement of SMT, associated patient profiles, and clinical outcomes in a real-world HF population. METHODS: Patients with HF treated with SMT derived from the Swedish ICD and Pacemaker Registry who received CRT between 2007 and 2020 were included in the study. Patient characteristics associated with a shorter or longer time to CRT implantation were assessed using multivariable logistic regression, and associations between the time from SMT to CRT implantation and clinical outcomes (mortality and morbidity) were analyzed using multivariable Cox regression. RESULTS: Of the 9,409 patients, 43.8% received CRT at <3 months of achieving SMT, 34.9% between 3 and 9 months, and 21.3% after 9 months. The time from SMT to CRT implantation decreased significantly over the study period. Independent determinants of shorter time to implantation included recent HF hospitalization, previous implantation of a defibrillator, and greater use of guideline-directed medical therapy, whereas a history of HF >6 months and ischemic heart disease were associated with a longer time. After adjustments, there was a 9% lower risk of cardiovascular death with a shorter time from SMT to CRT implantation of <3 months vs 3-9 months (P = 0.045). A delayed time of >9 months vs 3-9 months was associated with a 13% higher risk of cardiovascular death/HF hospitalization, a 12% higher risk of cardiovascular death (P = 0.040), and an 11% higher risk of first HF hospitalization (P = 0.013). CONCLUSIONS: Time from the achievement of SMT to CRT implantation decreased over the study period. Delayed CRT implantation beyond 3 months was associated with higher cardiovascular mortality compared with earlier implantation after GDMT optimization.
No takes yet. Share an insight, caveat, or question.
Villaschi et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: