PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 19, 2011European Journal of Heart Failure118 citationsOpen Access

The European Cardiac Resynchronization Therapy Survey: Comparison of Outcomes between De Novo Cardiac Resynchronization Therapy Implantations and Upgrades

View Full Paper
NBNigussie BogaleKWKlaus K. WitteSPSilvia G. Priori

Key Result

Upgrades to cardiac resynchronization therapy (28% of 2367 procedures) showed no significant differences in 1-year mortality, clinical outcomes, or complication rates compared with de novo implants.

Study Design

Type

Observational (n=2,367)

Multicenter

Yes

Structured PICO

Do clinical outcomes and complication rates differ between de novo CRT implantations and upgrades from existing pacemakers or ICDs in patients with chronic heart failure?

P
Population
2367 patients with chronic heart failure undergoing CRT implant procedures from 141 centres in 13 countries in Europe
I
Intervention
De novo cardiac resynchronization therapy (CRT) implantation
C
Comparator
Upgrade of a previously implanted device (pacemaker or implantable cardioverter-defibrillator) to CRT (n=692, 28%)
O
Outcome
1 year outcomes regarding New York Heart Association (NYHA) class, global patient assessment, hospitalizations, complications, and mortality

Upgrading an existing pacemaker or ICD to a CRT device yields similar clinical outcomes and complication rates as de novo CRT implantation at 1 year.

Limitations

  • Not a randomized clinical trial
  • Not subject to randomized clinical trials

Abstract

AIMS: Cardiac resynchronization therapy (CRT) is an effective treatment for a subset of patients with chronic heart failure. Data on the benefit of CRT in heart failure patients with previous right ventricular pacemakers or standard defibrillators are sparse. METHODS AND RESULTS: The European (HFA, Heart Failure Association/EHRA, European Heart Rhythm Association) CRT Survey enrolled patients from 141 centres in 13 countries in Europe collecting baseline demographic, echocardiographic, clinical, and implant data, with follow-up at ∼1 year. The present analysis reports implantation data and 1 year outcomes regarding New York Heart Association (NYHA) class, global patient assessment, hospitalizations, complications, and mortality in patients undergoing de novo CRT implantations compared with those receiving an upgrade of a previously implanted device (pacemaker or implantable cardioverter-defibrillators). This analysis includes 2367 CRT implant procedures of which 692 (28%) were upgrades to CRT. Distribution of NYHA functional class and left ventricular function were similar between the groups. Procedural duration was also similar, although fluoroscopy time was shorter in the 'upgrades'. There was no difference in the frequency of peri-procedural complications. There were similar improvements in NYHA functional class and similar reduction in QRS duration, but more patients reported unchanged global assessment status in the upgraded group. Total and cause-specific mortality at 1 year was low and the same in both groups. CONCLUSIONS: More than one quarter of all CRT procedures are upgrades from existing systems, although this group has not been subject to randomized clinical trials. Our data suggest that there are no significant differences in clinical outcomes or complication rates between upgrades and de novo procedures. Clinical study no NCT 01185392.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bogale et al. (2011) conducted an observational in Chronic heart failure (n=2,367). CRT upgrade vs. De novo CRT implantation was evaluated on 1-year outcomes regarding NYHA class, global patient assessment, hospitalizations, complications, and mortality. Upgrades to cardiac resynchronization therapy (28% of 2367 procedures) showed no significant differences in 1-year mortality, clinical outcomes, or complication rates compared with de novo implants.

synapsesocial.com/papers/6a0869129a6c4ba6e6109bebhttps://doi.org/10.1093/eurjhf/hfr085
Ask AI
Helpful
Bookmark
Share
View Full Paper