Why the study?
Estimating improvement in left ventricular function after aortic valve replacement is difficult, prompting evaluation of whether energy loss can predict postoperative left ventricular function.
Does the total energy loss to cardiac output (EL/CO) ratio predict left ventricular ejection fraction improvement after bioprosthetic aortic valve replacement?
Does the total energy loss to cardiac output (EL/CO) ratio predict left ventricular ejection fraction improvement after bioprosthetic aortic valve replacement?
The total energy loss to cardiac output ratio measured by 4D flow MRI strongly correlates with postoperative LVEF improvement in patients undergoing bioprosthetic AVR.
EL/CO ratio should not guide AVR valve selection; small case series leaves open its predictive value for LVEF recovery.
OBJECTIVES: It is difficult to estimate the improvement in left ventricular (LV) function after aortic valve replacement (AVR). The present study aimed to evaluate whether energy loss (EL) can predict the postoperative LV function after AVR. METHODS: Nine patients who underwent AVR with a bioprosthetic valve were enrolled in the present study. Porcine prostheses were used in 5 patients and bovine pericardial prostheses were used in 4 patients. The aortic flow pattern was visualized and EL and cardiac output (CO) were measured using 4-dimensional flow magnetic resonance imaging from the LV to the descending aorta; the EL/CO ratio in the extracted area was calculated as total EL/CO ratio. RESULTS: With a porcine valve, a severe helical flow was observed in the ascending aorta during the holosystolic phase. In contrast, with a bovine pericardial valve, straight transvalvular aortic flow was observed in the early systolic phase and 2 large vortical flows occurred on both sides of the greater and lesser curvature of the ascending aorta after the mid-systolic period. The total EL/CO ratio was strongly correlated with LV ejection fraction improvement after AVR (r = 0.74, P = 0.02). CONCLUSIONS: The aortic flow pattern is different between the porcine valve and bovine pericardial valve. The total EL/CO ratio is a valuable tool for evaluating the postoperative LV ejection fraction improvement after AVR. Optimization of total EL/CO ratio would have potential to improve haemodynamic performances after AVR.
No takes yet. Share an insight, caveat, or question.
Hohri et al. (2021) studied this question.