Why the study?
The burden of ventricular arrhythmias and the role of prophylactic implantable cardioverter-defibrillators in toxic dilated cardiomyopathy due to substance abuse are not well documented.
Does implantable cardioverter-defibrillator implantation reduce arrhythmic syncope, sudden cardiac death, or death of unknown cause in patients under 65 with toxic dilated cardiomyopathy due to substance abuse and LVEF < 35%?
Does implantable cardioverter-defibrillator implantation reduce arrhythmic syncope, sudden cardiac death, or death of unknown cause in patients under 65 with toxic dilated cardiomyopathy due to substance abuse and LVEF < 35%?
Prophylactic ICD implantation may not provide significant benefit in patients with toxic dilated cardiomyopathy due to substance abuse, as ventricular arrhythmias are infrequent and LVEF often recovers.
Answers are grounded in this paper and cite their sources.
ICD implantation should not yet change practice in toxic cardiomyopathy; leaves open whether randomized trials would show benefit in reversible LV dysfunction.
BACKGROUND: Toxic dilated cardiomyopathy (T-DCM) due to substance abuse is now recognized as a potential cause of severe left ventricular dysfunction. The burden of ventricular arrhythmias (VA) and the role of a prophylactic implantable cardioverter-defibrillator (ICD) are not well documented in this population. We aim to assess the usefulness of ICD implantation in a T-DCM cohort. METHODS: Patients younger than 65 years with a left ventricular ejection fraction (LVEF) < 35% followed at a tertiary center heart failure (HF) clinic between January 2003 and August 2019 were screened for inclusion. The diagnosis of T-DCM was confirmed after excluding other etiologies, and substance abuse was established according to the DSM-5 criteria. The composite primary endpoints were arrhythmic syncope, sudden cardiac death (SCD), or death of unknown cause. The secondary endpoints were the occurrence of sustained VA and/or appropriate therapies in ICD carriers. RESULTS: Thirty-eight patients were identified, and an ICD was implanted in 19 (50%) of these patients, only one for secondary prevention. The primary outcome was similar between the two groups (ICD vs. non-ICD; p = 1.00). After a mean follow-up of 33 ± 36 months, only two VA episodes were reported in the ICD group. Three patients received inappropriate ICD therapies. One ICD implantation was complicated with cardiac tamponade. Twenty-three patients (61%) had an LVEF ≥35% at 12 months. CONCLUSION: VA are infrequent in the T-DCM population. The prophylactic ICD benefit was not observed in our cohort. The ideal timing for potential prophylactic ICD implantation in this population needs further studies.
No takes yet. Share an insight, caveat, or question.
Dognin et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: