Key result
Intravenous sedation with meperidine-diazepam for peritoneoscopy caused serious arterial oxygen desaturation, decreasing mean oxygen saturation from 94.7% at baseline to a nadir of 78.6%.
Why the study?
Does intravenous sedation with meperidine-diazepam alter oxygen saturation and ventilation in patients undergoing peritoneoscopy?
Observational (n=11)
Does intravenous sedation with meperidine-diazepam alter oxygen saturation and ventilation in patients undergoing peritoneoscopy?
Intravenous sedation with meperidine-diazepam during peritoneoscopy causes significant respiratory depression, leading to hypoxemia, hypercarbia, and acidosis.
Answers are grounded in this paper and cite their sources.
May warrant oximetry caution with meperidine-diazepam sedation; leaves open prospective trials on monitoring and alternatives.
The effect of intravenous sedation on oxygen saturation and ventilation was studied in 11 patients undergoing peritoneoscopy. Oxygen saturation (mean +/- SD) decreased from baseline (94.7% +/- 1.7%) to nadir (78.6% +/- 10.7%) after sedation. Respiratory depression was evident in these patients by concomitant decreases in minute ventilation and tidal volume. Baseline to nadir arterial blood gas changes in eight patients were consistent with hypoventilation and also suggested a superimposed ventilation perfusion mismatch. Mean respiratory rate did not significantly change during peritoneoscopy. Peritoneal gas insufflation stimulated increased ventilation and oxygen saturation, but no further changes in PCO2 or pH. We conclude that serious arterial oxygen desaturation and possibly some ventilation perfusion mismatch occur after sedation with intravenously administered meperidine-diazepam for peritoneoscopy with resultant hypoxemia, hypercarbia, and acidosis.
No takes yet. Share an insight, caveat, or question.
Charles E. Brady (1989) conducted an observational in Patients undergoing peritoneoscopy (n=11). Intravenous sedation (meperidine-diazepam) vs. Baseline was evaluated on Oxygen saturation. Intravenous sedation with meperidine-diazepam for peritoneoscopy caused serious arterial oxygen desaturation, decreasing mean oxygen saturation from 94.7% at baseline to a nadir of 78.6%.
Synapse has enriched 10 related papers. Consider them for comparative context: