Key result
Defibrillation threshold testing success does not differ across CKD stages, with a 3.5% complication rate.
Why the study?
Routine defibrillation threshold testing during ICD implantation is no longer recommended, but patients with severe CKD were excluded from pivotal trials and international guidelines lack guidance on kidney function effects.
Does the stage of chronic kidney disease affect the success and safety of defibrillation threshold testing in patients undergoing primary transvenous ICD implantation?
Cohort (n=451)
Does the stage of chronic kidney disease affect the success and safety of defibrillation threshold testing in patients undergoing primary transvenous ICD implantation?
Defibrillation threshold testing success and safety do not significantly differ across CKD stages, supporting the guideline that routine testing is not required even in patients with advanced CKD.
Answers are grounded in this paper and cite their sources.
Supports guideline against routine DFT testing in advanced CKD; observational data leaves open need for randomized confirmation.
INTRODUCTION: Routine defibrillation threshold (DFT) testing at the time of implantable cardioverter-defibrillator (ICD) implantation is no longer recommended because testing did not improve shock efficacy or reduce arrhythmic death. However, patients with severe chronic kidney disease (CKD) were not included in these trials and might benefit from DFT testing. International guidelines shed no light on the subject of the effect of kidney function on DFT testing in patients with CKD. METHODS: In this retrospective study, we aimed to identify the success and safety of DFT in patients with CKD stages 1-5 (ages 55-80 years) undergoing primary transvenous ICD implantation. RESULTS: A total of 451 patients were stratified into three groups based on kidney function: group 1 with CKD stage 1-2 (n = 294), group 2 with CKD stage 3-4 (n = 90), and group 3 with CKD stage 5 (n = 67). Ventricular fibrillation was induced 827 times. The median number of threshold testing per patient was two (interquartile range 1-2; range 1-7). No evidence of between CKD-group differences in ICD defibrillation success rates could be found when using all patient attempts, regardless of correction for energy levels (p = 0.262). DFT-related complications occurred in 16 patients (3.5%), predominantly hypoxemia due to hypoventilation (1.6%) and atrial arrhythmias. Five patients (1.1%) underwent ICD or lead revision following abnormal DFT test results. CONCLUSIONS: We did not demonstrate a correlation between CKD and increased DFT or an increased rate of inadequate defibrillation safety margin. DFT testing is feasible with a low risk of serious complications in patients with moderate and advanced CKD when clinically deemed necessary. DFT testing is not routinely required in patients with (advanced) CKD.
No takes yet. Share an insight, caveat, or question.
Timal et al. (2025) conducted a cohort in Chronic kidney disease undergoing primary transvenous ICD implantation (n=451). Defibrillation threshold (DFT) testing vs. Different CKD stages (CKD 1-2 vs 3-4 vs 5) was evaluated on ICD defibrillation success rates (p=0.262). Defibrillation threshold testing success rates did not differ across chronic kidney disease stages 1-5, with a low overall complication rate of 3.5%.