Key result
Optical mapping and 3D modeling demonstrated that transmural uncoupling is likely due to heterogeneous gap junction expression, with lambda(TM) reduced by 14 +/- 2% in subepicardial layers.
Transmural uncoupling at the epicardial-midmyocardial interface may be attributable to heterogeneous expression of cardiac gap junctions rather than rotational anisotropy.
Hypothesis-generating for gap junction-targeted conduction research in animals; leaves open human translation.
Previously, we showed that intercellular uncoupling through gap junctions is an important mechanism for maintaining transmural heterogeneities of repolarization that are responsible for ventricular arrhythmias in disease states such as heart failure. However, rotational anisotropy between transmural muscle layers also may influence coupling. To determine the effect of rotational anisotropy on transmural coupling, we developed a numerical three-dimensional model of passive cardiac tissue in which rotational anisotropy was varied in a controlled fashion. Simulations of optical mapping demonstrated that spatial averaging produced a voltage decay in space best fit by a single decaying exponential compared with the theoretically predicted decay. As fiber orientation varied by 90 degrees with respect to the transmural surface, the effective transmural space constant (lambda(TM)) changed by only 0.31% in simulations. In contrast, reducing intercellular conductivity by 24% decreased lambda(TM) by 7.7%. In the canine wedge preparation (n = 5), lambda measured by optical mapping of the epicardial and subepicardial surface was similar transverse (lambda(TV) = 0.73 +/- 0.10 mm) and transmural (lambda(TM) = 0.70 +/- 0.08 mm) to subepicardial fibers. We confirmed previous findings that lambda(TM) in subepicardial layers was significantly reduced by 14 +/- 2% compared with deeper layers of myocardium, providing evidence for transmural uncoupling in the epicardial-midmyocardial interface. These data establish the theoretical and experimental basis for measuring intercellular coupling between muscle layers spanning the ventricular wall with optical mapping techniques. Furthermore, this study demonstrates that transmural uncoupling at the epicardial-midmyocardial interface may be attributable to heterogeneous expression of cardiac gap junctions and not rotational anisotropy.
No takes yet. Share an insight, caveat, or question.
Poelzing et al. (2005) studied Ventricular arrhythmias (n=5). Optical mapping and numerical 3D modeling was evaluated on Effective transmural space constant (lambda(TM)). Optical mapping and 3D modeling demonstrated that transmural uncoupling is likely due to heterogeneous gap junction expression, with lambda(TM) reduced by 14 +/- 2% in subepicardial layers.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: