Key result
Semi-automated computerised CT methods distinguished schizophrenics from controls while reducing partial volume artefact, which caused a >2-fold variation in ventricular size with manual methods.
Why the study?
Do computerised CT measurement methods improve the validity and reliability of ventricular size assessment in schizophrenia compared to linear and planimetric methods?
Case-Control (n=55)
Do computerised CT measurement methods improve the validity and reliability of ventricular size assessment in schizophrenia compared to linear and planimetric methods?
Computerised methods for measuring brain ventricular size on CT scans reduce partial volume artefact compared to linear and planimetric methods, improving measurement validity and reliability.
Computerised CT methods may enhance ventricular measurement reliability in schizophrenia; leaves open effects on clinical decision-making.
There has been a considerable range in both the prevalence of ventricular enlargement and values for ventricular size of both schizophrenics and controls, in studies using computerised tomography (CT). The CT scans of 19 unrelated chronic schizophrenics, all of monozygotic (MZ) twin birth, and 36 age-and-sex-matched normal twins from 18 MZ pairs were examined by linear, planimetric, and semi-automated computerised methods. All methods distinguished schizophrenics from controls at approximately the same level of significance, but partial volume artefact led to a greater than two-fold variation in apparent ventricular size, and significantly reduced the validity and reliability of mechanical planimetric and linear measures. Measurement error may be an important source of artefact in uncontrolled studies using those techniques, and when comparing absolute values across studies, but the use of computerised methods should significantly reduce this source of artefact and allow more meaningful comparison.
No takes yet. Share an insight, caveat, or question.
Michael A. Reveley (1985) conducted a case-control in Schizophrenia (n=55). Semi-automated computerised CT measurement vs. Linear and planimetric CT measurement was evaluated on Ventricular size and differentiation of schizophrenics from controls. Semi-automated computerised CT methods distinguished schizophrenics from controls while reducing partial volume artefact, which caused a >2-fold variation in ventricular size with manual methods.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: