Why the study?
A novel grid mapping catheter collecting bipolar signals along and across splines may improve LA voltage mapping efficiency independent of propagation direction compared to conventional circular mapping catheters.
Does a grid mapping catheter improve mapping efficiency and LVA identification compared to a conventional circular mapping catheter in patients undergoing repeat ablation for recurrent atrial fibrillation?
Does a grid mapping catheter improve mapping efficiency and LVA identification compared to a conventional circular mapping catheter in patients undergoing repeat ablation for recurrent atrial fibrillation?
The grid mapping catheter provides more efficient left atrial voltage mapping with fewer catheter-induced ectopies and more selective identification of low-voltage areas compared to a conventional circular mapping catheter.
Answers are grounded in this paper and cite their sources.
GMC may enable faster mapping with refined LVA detection in repeat AF; leaves open impact on outcomes versus CMC.
Introduction A recently introduced grid mapping catheter (GMC) is designed for better electrode‐tissue contact and can collect bipolar signals both along and across the splines, which may allow more efficient voltage map generation independent of propagation direction. We compared the GMC with a conventional circular mapping catheter (CMC) for left atrial (LA) voltage mapping. Methods This study included 20 consecutive patients undergoing repeat ablation for recurrent atrial fibrillation who had demonstrated LA low‐voltage areas (LVAs, <0.10 mV). Following pulmonary vein isolation, LA voltage mapping was performed twice, once using the GMC and once using the CMC. Results Voltage mapping was more efficient using the GMC than the CMC in terms of mapping time (459 [404, 543] vs 602 [496, 814] seconds; P = .014) and the number of mapping points (2446 [2099, 3104] vs 1841 [1494, 2314]; P = .002). The incidence of catheter‐induced ectopies was lower (44 [28, 62] vs 114 [74, 188]; P < .0001) using the GMC. The GMC utilizing all bipoles detected LVAs in 85% of patients with LVAs detected by CMC. LVA measurements were significantly smaller on maps generated by the GMC using bipoles along or across the splines than those measured with the CMC (11.1 [4.6, 17.2] or 9.7 [2.5, 16.0] vs 16.4 [6.8, 26.8] cm 2 ; P = .008 and P = .001, respectively), and were even smaller when using all bipoles (7.9 [1.1, 13.5] cm 2 , P = .0001). Conclusion The GMC allowed a more efficient mapping procedure and enabled more selective identification of LVAs with smaller LVA size.