Key result
SAVR with Magna Ease bioprosthesis maintains ~97% freedom from SVD over a decade.
Why the study?
Candidates for SAVR are evolving and the Perimount Magna Ease bioprosthesis was relatively recently introduced, prompting evaluation of its long-term results.
What are the long-term clinical and echocardiographic outcomes of the Magna Ease pericardial aortic bioprosthesis in patients undergoing surgical aortic valve replacement?
Cohort (n=1,016)
No
What are the long-term clinical and echocardiographic outcomes of the Magna Ease pericardial aortic bioprosthesis in patients undergoing surgical aortic valve replacement?
The Magna Ease pericardial aortic bioprosthesis demonstrates excellent long-term durability with 96.5% freedom from structural valve deterioration at 10 years.
OBJECTIVES: The population of candidates to surgical aortic valve replacement (SAVR) is evolving. The Perimount Magna Ease© bioprosthesis has been introduced relatively recently in the practice. We aimed at evaluating its long-term results. METHODS: This article describes a single-centre cohort of 1016 consecutive SAVRs with the Magna Ease© valve (2008-2014), consisting of an all-comers population. We performed a prospective collection of in-hospital data, systematic clinical and echocardiographic follow-up. Valve-related events were as follows: structural valve deterioration (SVD; according to modified definition criteria), nonstructural valve dysfunction, patient-prosthesis mismatch (PPM). RESULTS: Age at SAVR was 73.4 ± 9.5 years; calcified aortic stenosis was the indication to surgery in 59.6%. A total of 974 patients entered the follow-up; 564 were alive at the last follow-up (median duration: 9.8 years) (up to 13.4 years). New York Heart Association class was I or II in 92.1%. Overall survival at 10 years was 56.8 ± 1.8%. Freedom from SVD at 10 was 96.5 ± 0.8% (Kaplan-Meier) and 97.4 ± 0.6% (competing risks) (28 SVD events after 6.9 ± 3.3 years). There were 15 reinterventions for SVD (redo-SAVR and Transcatheter Aortic Valve Implantation (TAVI)); 10-year freedom from reintervention was 97.8 ± 0.6%. Moderate and severe PPM occurred in 26.8% and 5.4%, respectively, without association with late mortality (P = 0.12 for moderate and P = 0.70 for severe PPM). Freedom from valve-related mortality was 97.8 ± 0.5% at 10 years. CONCLUSIONS: In this follow-up of the Magna Ease bioprosthesis for SAVR, data indicate good late outcomes (30-day outcomes are excluded). Continued follow-up is required to further support its use in patients with life expectancy >10-12 years.
No takes yet. Share an insight, caveat, or question.
Anselmi et al. (2023) conducted a cohort in Aortic valve disease requiring surgical aortic valve replacement (n=1,016). Magna Ease pericardial aortic bioprosthesis was evaluated on Freedom from structural valve deterioration (SVD) at 10 years. Surgical aortic valve replacement with the Magna Ease bioprosthesis demonstrated good long-term durability, with 96.5% freedom from structural valve deterioration at 10 years.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: