Key result
The use of a novel SafeSept transseptal guidewire achieved successful left atrial access in 97.6% of patients undergoing transseptal puncture, with no attributable serious complications.
Why the study?
Does a novel transseptal guidewire facilitate safe and effective transseptal puncture in patients undergoing atrial ablation?
Observational (n=210)
Does a novel transseptal guidewire facilitate safe and effective transseptal puncture in patients undergoing atrial ablation?
The SafeSept transseptal guidewire provides a safe and highly effective method for achieving left atrial access during catheter ablation procedures.
Supports SafeSept guidewire feasibility for transseptal access; leaves open randomized comparison to standard techniques.
AIMS: An increasing number of transseptal punctures (TSPs) are performed worldwide for atrial ablations. Transseptal punctures can be complex and can be associated with potentially life threatening complications. The purpose of the study was to evaluate the safety and efficacy of a novel transseptal guidewire (TSGW) designed to facilitate TSPs. METHODS AND RESULTS: Transseptal punctures were performed using a SafeSept TSGW passed through a standard TSP apparatus. Transseptal punctures were performed by standard technique with additional use of a TSGW allowing probing of the interatrial septum without needle exposure and penetration of the fossa into the left atrium (LA). Transseptal puncture using the TSGW was performed in 210 patients. Left atrial access was achieved successfully in 205 of 210 patients (97.6%) and in 96.3% of patients undergoing repeat TSP. Left atrial access was achieved with the first pass in 81.2% (mean 1.4 ± 0.9 passes, range 1-6) using the TSGW. No serious complications were attributable to the use of the TSGW, even in cases of failed TSP. CONCLUSIONS: The TSGW is associated with a high success rate for TSP and may be a useful alternative to transoesophageal or intracardiac echocardiogram-guided TSP.
No takes yet. Share an insight, caveat, or question.
Wadehra et al. (2011) conducted an observational in Patients undergoing transseptal puncture for atrial ablation (n=210). SafeSept transseptal guidewire (TSGW) was evaluated on Successful left atrial access. The use of a novel SafeSept transseptal guidewire achieved successful left atrial access in 97.6% of patients undergoing transseptal puncture, with no attributable serious complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: