Key result
Carotid to femoral pulse wave velocity measured with the Vicorder device in healthy, normotensive patients averaged 6.1±1.4 m/s and significantly increased with age (r=0.842; P<0.0001).
Why the study?
What are the reference values for carotid to femoral pulse wave velocity measured with the Vicorder device in healthy, normotensive individuals?
Cross-Sectional (n=318)
What are the reference values for carotid to femoral pulse wave velocity measured with the Vicorder device in healthy, normotensive individuals?
The study establishes reference values for carotid to femoral pulse wave velocity using the oscillometric Vicorder device in healthy individuals, facilitating its use in cardiovascular risk stratification.
Answers are grounded in this paper and cite their sources.
Supplies Vicorder-specific normative cfPWV data; leaves open prospective validation before clinical risk stratification use.
Carotid to femoral pulse wave velocity (PWV) is associated with an increase in cardiovascular morbidity and all-cause mortality. Noninvasive approach has made this method applicable for the examination of larger populations. This study aimed to obtain reference values of PWV measured with the Vicorder device. PWV was obtained using the oscillometric Vicorder in 318 healthy, normotensive patients (165 women, 28.7±17.6 years, range 6-83 years). A plethysmographic sensor was placed over the right carotid region to pick up the carotid pulse wave and a blood pressure cuff was placed around the upper thigh to trace the femoral pulse wave. Path length was defined as the distance from the suprasternal notch to the top of the thigh cuff. Mean PWV was 6.1±1.4 m/s and significantly increased with age (r=.842; P<.0001). PWV was associated with mean arterial pressure (r=.546; P<.0001) and body mass index (r=.396; P<.0001). In a multiple linear regression model, age, mean arterial pressure, and body height emerged as independent markers for PWV. This study established reference values for carotid to femoral PWV derived by oscillometric measures that can now be used for risk stratification.
No takes yet. Share an insight, caveat, or question.
Müller et al. (2012) conducted a cross-sectional in Healthy, normotensive (n=318). Vicorder device was evaluated on Mean carotid to femoral pulse wave velocity (PWV). Carotid to femoral pulse wave velocity measured with the Vicorder device in healthy, normotensive patients averaged 6.1±1.4 m/s and significantly increased with age (r=0.842; P<0.0001).