Key result
4D flow MRI reveals high-velocity entry tear flow foreshadowing decompensation in acute type B aortic dissection.
Why the study?
Because Stanford type B aortic dissection can be managed medically or surgically, identifying predictors of adverse outcomes is important to risk-stratify patients for preemptive surgical procedures.
Can 4D flow MRI identify predictors of adverse outcomes in patients with acute type B aortic dissection?
Case Report (n=1)
Can 4D flow MRI identify predictors of adverse outcomes in patients with acute type B aortic dissection?
4D flow MRI is feasible in patients with acute type B aortic dissection and can provide valuable hemodynamic information to help risk-stratify patients for medical versus surgical management.
Hypothesis-generating for 4D flow MRI risk stratification in acute type B aortic dissection; prospective validation required before clinical use.
Stanford type B aortic dissection (TBAD) is a potentially fatal condition involving a tear in the descending aorta. As TBAD can be managed with medical therapy or surgical repair, identifying predictors of adverse outcomes is important to risk-stratify patients for preemptive surgical procedures. 4D flow magnetic resonance imaging (MRI) has shown to be useful in characterizing the complex hemodynamics seen in TBAD patients and correlating flow patterns with adverse outcomes. We report a case of a 58-year-old man who presented to the hospital with acute TBAD and a large primary entry tear. He was initially managed with medical therapy due to his stable clinical status and computed tomographic angiography showing a stable dissection. However, 4D flow MRI showed high velocity flow through the entry tear, which foreshadowed the later clinical decompensation of the patient. Our case demonstrates that performing 4D flow MRI on TBAD patients is feasible and can provide valuable information in the decision to pursue medical or surgical management.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2023) conducted a case report in Acute type B aortic dissection (n=1). 4D flow MRI was evaluated. 4D flow MRI demonstrated high velocity flow through the entry tear in a patient with acute type B aortic dissection, foreshadowing clinical decompensation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: