Key result
Computer-assisted CRT platforms show near-perfect correlation with offline diagnostic tools for LV function assessment.
Why the study?
Does a computer-assisted interventional CRT platform accurately measure LV function parameters compared to offline diagnostic tools in patients undergoing CRT evaluation?
Observational (n=19)
Does a computer-assisted interventional CRT platform accurately measure LV function parameters compared to offline diagnostic tools in patients undergoing CRT evaluation?
Answers are grounded in this paper and cite their sources.
A novel computer-assisted interventional CRT platform demonstrates excellent accuracy in measuring LV function parameters compared to standard offline tools, potentially aiding in real-time identification of CRT responders.
Cardiac resynchronisation therapy (CRT) is an established treatment for symptomatic patients with heart failure, a prolonged QRS duration, and impaired left ventricular (LV) function; however, non-response rates remain high. Recently proposed computer-assisted interventional platforms for CRT provide new routes to improving outcomes. Interventional systems must process information in an accurate, fast and highly automated way that is easy for the interventional cardiologists to use. In this paper, an interventional CRT platform is validated against two offline diagnostic tools to demonstrate that accurate information processing is possible in the time critical interventional setting. The study consisted of 3 healthy volunteers and 16 patients with heart failure and conventional criteria for CRT. Data analysis included the calculation of end-diastolic volume, end-systolic volume, stroke volume and ejection fraction; computation of global volume over the cardiac cycle as well as time to maximal contraction expressed as a percentage of the total cardiac cycle. The results showed excellent correlation ( R² values of $$>\,0.99$$ and Pearson correlation coefficient of $$>\,0.98$$ ) with comparable offline diagnostic tools. Results confirm that our interventional system has good accuracy in everyday clinical practice and can be of clinical utility in identification of CRT responders and LV function assessment.
No takes yet. Share an insight, caveat, or question.
Panayiotou et al. (2018) conducted an observational in Heart failure (n=19). Computer-assisted interventional platform for CRT vs. Two offline diagnostic tools was evaluated on Correlation of LV function parameters (EDV, ESV, SV, EF, global volume, time to maximal contraction) with offline tools (R^2 > 0.99, Pearson > 0.98). A computer-assisted interventional platform for CRT showed excellent correlation with offline diagnostic tools for LV function assessment.