Why the study?
Temporal changes in outcomes among heart failure patients receiving cardiac resynchronization therapy with a defibrillator were unknown.
Does CRT-D implantation in a more recent era (2018-2021) improve outcomes compared to an older era (2011-2015) in heart failure patients?
Observational (n=1,517)
Yes
Does CRT-D implantation in a more recent era (2018-2021) improve outcomes compared to an older era (2011-2015) in heart failure patients?
Effect estimate: aHR 0.72 (95% CI 0.55-0.94)
Absolute Event Rate: 13% vs 18%
p-value: p=0.017
Outcomes for heart failure patients receiving CRT-D have improved over time, with significant reductions in all-cause mortality, noncardiac death, and inappropriate ICD therapies in the 2018-2021 era compared to 2011-2015.
Background Temporal change in outcomes of heart failure patients receiving cardiac resynchronization therapy with a defibrillator (CRT‐D) is unknown. Methods We assess outcomes and underlying heart diseases of patients receiving CRT‐D with analyzing database of the Japan cardiac device treatment registry (JCDTR) at the implantation year 2011–2015 and New JCDTR at the implantation year 2018–2021. Results Proportion of nonischemic heart diseases was about 70% in both the groups (JCDTR: 69%; New JCDTR: 72%). Cardiac sarcoidosis increased with the rate of 5% in the JCDTR to 9% in the New JCDTR group. During an average follow‐up of 21 months, death from any cause occurred in 167 of 906 patients in the JCDTR group (18%) and 79 of 611 patients in the New JCDTR group (13%) (adjusted hazard ratio [aHR] in the New JCDTR group, 0.72; 95% confidence interval [CI]: 0.55–0.94; p = .017). The superiority was mainly driven by reduction in the risk of noncardiac death. With regard to appropriate and inappropriate implantable cardioverter–defibrillator (ICD) therapy, there was a significant reduction in the New JCDTR group versus the JCDTR group (aHR in the New JCDTR group, 0.76; 95% CI: 0.59–0.98; p = .032 for appropriate ICD therapy; aHR in the New JCDTR group, 0.24; 95% CI: 0.12–0.50; p < .0001 for inappropriate ICD therapy). Conclusions All‐cause mortality was reduced in CRT‐D patients implanted during 2018–2021 compared to those during 2011–2015, with a significant reduction in noncardiac death.
No takes yet. Share an insight, caveat, or question.
Yokoshiki et al. (2023) conducted an observational in Systolic heart failure (n=1,517). CRT-D implantation during 2018-2021 vs. CRT-D implantation during 2011-2015 was evaluated on Death from any cause (aHR 0.72, 95% CI 0.55-0.94, p=0.017).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: