Key result
Cardiac resynchronization therapy with a defibrillator (CRT-D) reduced all-cause mortality compared to a pacemaker (CRT-P) in patients with heart failure (adjusted HR 0.85; 95% CI 0.76-0.94; p<0.01).
Why the study?
To evaluate the impact of CRT-D versus CRT-P on mortality, assess subgroup effects, and analyze time trends in treatment effects and patient characteristics given changing indications over recent decades.
Does cardiac resynchronization therapy with a defibrillator (CRT-D) reduce all-cause mortality compared with CRT-P in patients with heart failure?
Meta-Analysis (n=128,030)
Yes
Does cardiac resynchronization therapy with a defibrillator (CRT-D) reduce all-cause mortality compared with CRT-P in patients with heart failure?
Hazard Ratio: 0.85 (95% CI 0.76–0.94)
p-value: p=< 0.01
This meta-analysis demonstrates that CRT-D provides an overall mortality benefit compared to CRT-P in HFrEF patients, although this advantage is attenuated or absent in older patients (>75 years) and those with non-ischemic etiology.
AIMS: This study aimed to investigate the impact of cardiac resynchronization therapy with a defibrillator (CRT-D) on mortality, comparing it with CRT with a pacemaker (CRT-P). Additionally, the study sought to identify subgroups, evaluate the time trend in treatment effects, and analyze patient characteristics, considering the changing indications over the past decades. METHODS AND RESULTS: PubMed, CENTRAL, and Embase up to October 2021 were screened for studies comparing CRT-P and CRT-D, focusing on mortality. Altogether 26 observational studies were selected comprising 128 030 CRT patients, including 55 469 with CRT-P and 72 561 with CRT-D device. Cardiac resynchronization therapy with defibrillator was able to reduce all-cause mortality by almost 20% over CRT-P [adjusted hazard ratio (HR): 0.85; 95% confidence interval (CI): 0.76-0.94; P < 0.01] even in propensity-matched studies (HR: 0.83; 95% CI: 0.80-0.87; P < 0.001) but not in those with non-ischaemic aetiology (HR: 0.95; 95% CI: 0.79-1.15; P = 0.19) or over 75 years (HR: 1.08; 95% CI 0.96-1.21; P = 0.17). When treatment effect on mortality was investigated by the median year of inclusion, there was a difference between studies released before 2015 and those thereafter. Time-trend effects could be also observed in patients' characteristics: CRT-P candidates were getting older and the prevalence of ischaemic aetiology was increasing over time. CONCLUSION: The results of this systematic review of observational studies, mostly retrospective with meta-analysis, suggest that patients with CRT-D had a lower risk of mortality compared with CRT-P. However, subgroups could be identified, where CRT-D was not superior such as non-ischaemic and older patients. An improved treatment effect of CRT-D on mortality could be observed between the early and late studies partly related to the changed characteristics of CRT candidates.
No takes yet. Share an insight, caveat, or question.
Veres et al. (2023) conducted a meta-analysis in Heart failure with reduced left ventricular function (HFrEF) and wide QRS (n=128,030). Cardiac resynchronization therapy with a defibrillator (CRT-D) vs. Cardiac resynchronization therapy with a pacemaker (CRT-P) was evaluated on All-cause mortality (adjusted HR 0.85, 95% CI 0.76-0.94, p=< 0.01). Cardiac resynchronization therapy with a defibrillator (CRT-D) reduced all-cause mortality compared to a pacemaker (CRT-P) in patients with heart failure (adjusted HR 0.85; 95% CI 0.76-0.94; p<0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: