Key result
Robust optimization or expanded margins in VT carbon-ion radiotherapy limit motion-induced target coverage loss to ~5%.
Why the study?
Favorable clinical outcomes of CIRT for ventricular arrhythmia have been reported, but optimal treatment strategies remain to be explored by assessing plan robustness against cardiac motion.
Does robust optimization or a 5-mm margin improve target coverage in carbon-ion radiotherapy plans for ventricular tachycardia?
Does robust optimization or a 5-mm margin improve target coverage in carbon-ion radiotherapy plans for ventricular tachycardia?
Accounting for cardiac motion using ECG-gated CT with robust optimization or a 5-mm margin significantly improves target coverage in carbon-ion radiotherapy for ventricular tachycardia.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for motion-robust carbon-ion VT planning; prospective trials needed before clinical adoption.
Favorable clinical outcomes of carbon-ion radiotherapy (CIRT) for ventricular arrhythmia have been reported, and optimal treatment strategies are being explored. We assessed the robustness of CIRT plans against cardiac motion in ventricular tachycardia. Electrocardiographic (ECG)-gated computed tomography (CT) images at end-diastole and end-systole were used for planning, and dose distributions were recalculated on the opposite phase to evaluate dosimetric changes. Cardiac motion reduced target coverage by about 13.8-19.0%, whereas a 5-mm margin or robust optimization reduced the decrease approximately to 5%. An optimization approach that accounts for cardiac motion using ECG-gated CT provided a favorable balance for clinical application.
No takes yet. Share an insight, caveat, or question.
Miyasaka et al. (2026) studied Ventricular tachycardia. Carbon-ion radiotherapy (CIRT) with robust optimization or 5-mm margin vs. Standard planning was evaluated on Target coverage reduction due to cardiac motion. Robust optimization or a 5-mm margin in carbon-ion radiotherapy planning for ventricular tachycardia reduced the target coverage decrease caused by cardiac motion from 13.8-19.0% to approximately 5%.
Synapse has enriched 10 related papers. Consider them for comparative context: