Key result
Visualizing the tricuspid valve annulus during HBP reduces fluoroscopy time ~30% vs standard placement.
Why the study?
His bundle pacing adoption is limited by longer procedure times and frequent high capture thresholds, prompting evaluation of whether a novel imaging technique improves implantation.
Does His bundle pacing implantation with visualization of the tricuspid valve annulus reduce fluoroscopic time in patients with standard pacing indications?
RCT (n=50)
Does His bundle pacing implantation with visualization of the tricuspid valve annulus reduce fluoroscopic time in patients with standard pacing indications?
Absolute Event Rate: 7.1% vs 10.1%
p-value: p=0.03
Visualization of the tricuspid valve annulus via contrast injection significantly reduces procedural and fluoroscopic times during His bundle pacing implantation.
No takes yet. Share an insight, caveat, or question.
Reduces fluoroscopy time in HBP implantation; extends RCT evidence for techniques to overcome procedural barriers in physiological pacing.
Gu et al. (2020) conducted an RCT in standard pacing indications (n=50). His bundle pacing with visualization of the tricuspid valve annulus vs. standard method was evaluated on fluoroscopic time for HBP lead placement (minutes) (p=0.03). His bundle pacing with visualization of the tricuspid valve annulus significantly reduced fluoroscopic time for lead placement compared to the standard method (7.1 vs 10.1 minutes, P=0.03).