Key result
ORI-O-CSPAMM cuts scan time ~50% vs CSPAMM and ORI-CSPAMM while removing off-resonance artifacts.
Why the study?
The study was designed to develop an Off-Resonance Insensitive Orthogonal CSPAMM sequence (ORI-O-CSPAMM) to acquire CSPAMM and MICSR grids in half of the acquisition time.
Does the ORI-O-CSPAMM sequence improve image quality and reduce scan time compared to standard CSPAMM sequences in MRI tagging?
Does the ORI-O-CSPAMM sequence improve image quality and reduce scan time compared to standard CSPAMM sequences in MRI tagging?
Answers are grounded in this paper and cite their sources.
The novel ORI-O-CSPAMM sequence effectively removes off-resonance artifacts and halves the scan time required for cardiac MRI tagging, facilitating its potential application in clinical protocols.
PURPOSE: To develop an Off-Resonance Insensitive Orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half of the acquisition time. METHODS: Phantom and mid-level left ventricle short-axis tagged images were acquired using CSPAMM, ORI-CSPAMM, O-CSPAMM, and the proposed ORI-O-CPAMM sequences to interrogate and compare its behavior under off-resonance effects produced by vegetable oil and subcutaneous and epicardial fat. The images were compared in terms of signal and the capacity to obtain complex difference and MICSR images. RESULTS: Like ORI-CSPAMM, the proposed ORI-O-CSPAMM sequence removed almost completely the off-resonance artifacts produced during the tagging preparation. Tagging grids without DC components were obtained with ORI-O-CSPAMM using complex difference and MICSR from only two complementary images, which reduced the scan time to a half compared to CSPAMM and ORI-CSPAMM. The removal of off-resonance effects and the capacity to obtain MICSR images are advantages of ORI-O-CSPAMM over the O-CSPAMM sequence. CONCLUSION: We developed a novel and fast tagging sequence designed to remove off-resonance effects during the tagging preparation, and to obtain complex difference and MICSR grids in half of the scan time compared to CSPAMM and ORI-CSPAMM sequences, which could allow its application to clinical protocols.
No takes yet. Share an insight, caveat, or question.
Mella et al. (2021) studied this question. ORI-O-CSPAMM sequence vs. CSPAMM, ORI-CSPAMM, and O-CSPAMM sequences was evaluated on Signal and capacity to obtain complex difference and MICSR images under off-resonance effects. The ORI-O-CSPAMM sequence removed off-resonance artifacts and obtained complex difference and MICSR grids in half the scan time compared to CSPAMM and ORI-CSPAMM sequences.
Synapse has enriched 10 related papers. Consider them for comparative context: