Key result
Contrast-free 3D MTR localizes myocardial scar in porcine models via ~33% lower values in infarcted tissue.
Why the study?
To develop a 3D high-resolution free-breathing magnetization transfer ratio sequence for contrast-free assessment of myocardial infarct and coronary vein anatomy.
Does a contrast-free 3D magnetization transfer ratio (MTR) sequence accurately detect myocardial scar and visualize coronary veins compared to LGE?
Does a contrast-free 3D magnetization transfer ratio (MTR) sequence accurately detect myocardial scar and visualize coronary veins compared to LGE?
Absolute Event Rate: 16.8% vs 25.1%
OBJECTIVE: To develop a three-dimensional (3D) high-resolution free-breathing magnetization transfer ratio (MTR) sequence for contrast-free assessment of myocardial infarct and coronary vein anatomy. MATERIALS AND METHODS: Two datasets with and without off-resonance magnetization transfer preparation were sequentially acquired to compute MTR. 2D image navigators enabled beat-to-beat translational and bin-to-bin non-rigid motion correction. Two different imaging sequences were explored. MTR scar localization was compared against 3D late gadolinium enhancement (LGE) in a porcine model of myocardial infarction. MTR variability across the left ventricle and vessel sharpness in the coronary veins were evaluated in healthy human subjects. RESULTS: A decrease in MTR was observed in areas with LGE in all pigs (non-infarct: 25.1 ± 1.7% vs infarct: 16.8 ± 1.9%). The average infarct volume overlap on MTR and LGE was 62.5 ± 19.2%. In humans, mean MTR in myocardium was between 37 and 40%. Spatial variability was between 15 and 20% of the mean value. 3D whole heart MT-prepared datasets enabled coronary vein visualization with up to 8% improved vessel sharpness for non-rigid compared to translational motion correction. DISCUSSION: MTR and LGE showed agreement in infarct detection and localization in a swine model. Free-breathing 3D MTR maps are feasible in humans but high spatial variability was observed. Further clinical studies are warranted.
No takes yet. Share an insight, caveat, or question.
López et al. (2020) studied Healthy subjects and myocardial infarction (porcine model) (n=13). 3D magnetization transfer ratio (MTR) imaging vs. Late gadolinium enhancement (LGE) and remote myocardium was evaluated on Magnetization transfer ratio (MTR) in infarcted vs non-infarcted myocardium. A contrast-free 3D magnetization transfer ratio sequence successfully localized myocardial scar, demonstrating decreased MTR in infarcted (16.8%) compared to remote myocardium (25.1%) in a porcine model.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: