Key result
Shorter distance between PVI lines linked to ~28% lower risk of roof-dependent atrial tachycardia.
Why the study?
Do anatomical parameters of the left atrium predict the occurrence of roof-dependent atrial tachycardia after pulmonary vein isolation in patients with atrial fibrillation?
Observational (n=265)
Do anatomical parameters of the left atrium predict the occurrence of roof-dependent atrial tachycardia after pulmonary vein isolation in patients with atrial fibrillation?
A shorter distance between PVI lines at the LA roof, greater left atrial volume index, and a Deep V shape of the LA roof are associated with the occurrence of roof-dependent atrial tachycardia after pulmonary vein isolation.
Answers are grounded in this paper and cite their sources.
Anatomical LA features may aid post-PVI risk stratification; leaves open whether targeted ablation reduces roof-dependent AT.
Background Roof‐dependent atrial tachycardia (roof AT) sometimes occurs after pulmonary vein isolation (PVI) of atrial fibrillation (AF). This study aimed to investigate the relationship between the anatomy of the residual left atrial posterior wall and occurrence of roof AT . Methods A total of 265 patients with AF who underwent PVI were enrolled. After the PVI, induced or recurrent roof AT was confirmed by an entrainment maneuver or activation mapping using a three‐dimensional (3D) mapping system. To identify the predictors of roof AT, the minimum distance between both PVI lines (d‐PVI) was measured by a 3D mapping system and the anatomical parameters, including the left atrial (LA) diameter, left atrial volume index (LAVi), and shape of the left atrial roof, were analyzed by 3D computed tomography . Results Roof AT was documented in 11 (4.2%) of 265 patients. A multivariable analysis demonstrated that the d‐PVI, Deep V shape of the LA roof, and LAVi were associated with roof AT occurrences (d‐PVI: odds ratio: 0.72, confidence interval [CI]: 0.61–0.86, P < 0.001; Deep V shape: odds ratio: 0.19, CI: 0.04–0.82, P = 0.03; LAVi: odds ratio: 1.05, CI: 1.02–1.07, P = 0.001). A receiver‐operating characteristic curve analysis yielded an optimal cut‐off value of 15.5 mm and 55.7 mL/m 2 for the d‐PVI and LAVi, respectively . Conclusion The shorter d‐PVI at the LA roof, greater LAVi, and Deep V shape were associated with the occurrence of a roof AT .
No takes yet. Share an insight, caveat, or question.
Matsumoto et al. (2016) conducted an observational in Atrial fibrillation (n=265). Pulmonary vein isolation was evaluated on Occurrence of roof-dependent atrial tachycardia (OR 0.72, 95% CI 0.61-0.86, p=< 0.001). Shorter distance between PVI lines, greater left atrial volume index, and Deep V shape were associated with roof-dependent atrial tachycardia after PVI.
Synapse has enriched 10 related papers. Consider them for comparative context: