Key result
A noncontact mapping system successfully guided radiofrequency ablation of ventricular tachycardia, with 77% of applications to identified diastolic activity achieving successful ablation (P<0.0001).
Why the study?
Does a noncontact multielectrode array mapping system safely map and guide radiofrequency ablation in patients with ventricular tachycardia?
Observational (n=24)
Does a noncontact multielectrode array mapping system safely map and guide radiofrequency ablation in patients with ventricular tachycardia?
A noncontact multielectrode array mapping system is feasible for identifying diastolic portions of VT circuits and guiding successful radiofrequency ablation.
Noncontact mapping guided VT ablation in this case; leaves open generalizability and need for prospective validation.
BACKGROUND: Catheter ablation of ventricular tachycardia (VT) is limited by difficulty in identifying suitable sites for ablation. This study assesses use of a system capable of simultaneous endocardial mapping of the human left ventricle to map and guide radiofrequency (RF) catheter ablation of VT. METHODS AND RESULTS: A catheter-mounted noncontact multielectrode array was used to reconstruct 3360 electrograms, superimposed onto a computer-simulated endocardial model. Of 24 patients studied, 20 had ischemic heart disease. Exit sites were demonstrated by the noncontact system in 80 (99%) of 81 VTs, with complete VT circuits traced in 17 (21%). In another 37 VTs, 36+/-30% (mean+/-SD) of the diastolic interval was identified. Thirty-eight VT morphologies were ablated with 154 RF energy applications. Successful ablation was achieved by 77% of RF applications to relevant diastolic activity identified by the system and was significantly more likely (P<0.0001) than by RF at the VT exit or remote from diastolic activation. Over a mean follow-up of 1.5 years, 14 patients (64%) have had no recurrence of VT, and only 2 target VTs (5.3%) have recurred. Five patients have had recurrence of other VTs. CONCLUSIONS: This noncontact mapping system identified diastolic portions of the circuit in most VTs studied and can safely map and guide ablation of human VT.
No takes yet. Share an insight, caveat, or question.
Schilling et al. (1999) conducted an observational in Ventricular Tachycardia (n=24). Noncontact multielectrode array mapping system was evaluated on Successful ablation (p=<0.0001). A noncontact mapping system successfully guided radiofrequency ablation of ventricular tachycardia, with 77% of applications to identified diastolic activity achieving successful ablation (P<0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More on Ventricular arrhythmiasMore from Circulation