Key result
An integrated 3-phase mapping technique for RF catheter ablation achieved a high long-term ablation success rate of 89% (17 of 19 patients) in patients with idiopathic ventricular tachycardia.
Why the study?
Does an integrated 3-phase mapping technique provide efficient and accurate localization for radiofrequency catheter ablation in patients with idiopathic ventricular tachycardia?
Cohort (n=19)
Does an integrated 3-phase mapping technique provide efficient and accurate localization for radiofrequency catheter ablation in patients with idiopathic ventricular tachycardia?
An integrated 3-phase mapping technique provides efficient and accurate localization for RF catheter ablation of idiopathic ventricular tachycardia, achieving high long-term success with few RF pulses.
Answers are grounded in this paper and cite their sources.
May support integrated mapping for idiopathic VT ablation; hypothesis-generating in small cohort, needs larger validation.
BACKGROUND: Radiofrequency (RF) catheter ablation provides curative treatment for idiopathic ventricular tachycardia (VT). METHODS AND RESULTS: Nineteen consecutive patients with an idiopathic VT underwent RF catheter ablation. An integrated 3-phase mapping approach was used, consisting of the successive application of online 62-lead body surface QRS integral mapping, directed regional paced body surface QRS integral mapping, and local activation sequence mapping. Mapping phase 1 was localization of the segment of VT origin by comparing the VT QRS integral map with a database of mean paced QRS integral maps. Mapping phase 2 was body surface pace mapping during sinus rhythm in the segment localized in phase 1 until the site at which the paced QRS integral map matched the VT QRS integral map was identified (ie, VT exit site). Mapping phase 3 was local activation sequence mapping at the circumscribed area identified in phase 2 to identify the site with the earliest local endocardial activation (ie, site of VT origin). This site became the ablation target. Ten VTs were ablated in the right ventricular outflow tract, 2 at the basal LV septum, and 7 at the midapical posterior left ventricle. A high long-term ablation success (mean follow-up duration, 14+/-9 months) was achieved in 17 of the 19 patients (89%) with a low number of RF pulses (mean, 3.3+/-2.2 pulses per patient). CONCLUSIONS: This prospective study shows that integrated 3-phase mapping for localization of the site of origin of idiopathic VT offers efficient and accurate localization of the target site for RF catheter ablation.
No takes yet. Share an insight, caveat, or question.
Peeters et al. (1999) conducted a cohort in Idiopathic ventricular tachycardia (n=19). Integrated 3-phase mapping technique for RF catheter ablation was evaluated on Long-term ablation success. An integrated 3-phase mapping technique for RF catheter ablation achieved a high long-term ablation success rate of 89% (17 of 19 patients) in patients with idiopathic ventricular tachycardia.
Synapse has enriched 10 related papers. Consider them for comparative context: