Key result
Leti Laboratories rivaroxaban demonstrates pharmacodynamic equivalence to the Bayer reference formulation.
Why the study?
The study was conducted to verify the pharmacodynamic efficacy and effect on prothrombin time of generic Rivaroxaban Leti 20 mg compared to reference Rivaroxaban Bayer 20 mg.
Does generic rivaroxaban 20 mg provide equivalent pharmacodynamic effects on prothrombin time compared to reference rivaroxaban 20 mg in healthy volunteers?
RCT (n=25)
Single-blind
Randomized
No
Does generic rivaroxaban 20 mg provide equivalent pharmacodynamic effects on prothrombin time compared to reference rivaroxaban 20 mg in healthy volunteers?
A generic formulation of rivaroxaban 20 mg demonstrated pharmacodynamic equivalence to the reference product in healthy volunteers, supporting its clinical interchangeability.
Answers are grounded in this paper and cite their sources.
Supports interchangeability of this generic rivaroxaban; confirms pharmacodynamic equivalence on PT ratios in healthy volunteers.
Background: The prevalence of both atrial fibrillation (FA) and diabetes mellitus (DM) is increasing and they often occur together and constitute a high risk of thrombosis. Rivaroxaban is a Factor Xa inhibitor with a rapid onset and disappearance of action after oral administration; it acts by inhibiting the active form of the coagulation factor. In order to reflect the effect of the action of Rivaroxaban, we used the prothrombin time (PT); however, it′s not the most accurate, but it is the one available in our community. Methods: This was a prospective, randomized, analyst-blinded, parallel group clinical study to verify the efficacy of Rivaroxaban Leti 20 mg (RL) (12 volunteers vs Rivaroxaban Bayer 20 mg (RB) (13 volunteers). The variables were determination of PT and Partial Thromboplastin Time (aPTT) at baseline and at 24, 48 and 72 hours after administering a daily dose of 20 mg for three days. The determination was carried out with the IDG method (Integrated Diagnostics Group Sanzay Corporation) with an International Sensitivity Index (ISI) of 1.17 PT and aPTT were taken before the first dose, and then, every day during the next 3 days, three hours after the ingestion of their daily dose at 7 am. Results: The 25 healthy volunteers were similar in age, BMI, and SBP/DBP level with a greater number of men in the Bayer group. The efficacy of rivaroxaban was similar in both groups with prolongation of PTT to the 2nd day of treatment with PT, and percentage changes from baseline (14.46 ± 0.97 for RB vs 14.17 ± 0.94 RL p: 0.45), PTT results and percentage changes from the base (RB: 34 ± 4.53 RL: 33.46 ± 2.82). The safety of rivaroxaban was good in both groups with no serious adverse events. The equivalence in the logarithmically transformed PT result (ln) on day two, Mean and CI (90%) 99.2 (94.4-104) and 100 (99.5-100.8); neither the means nor the 90% confidence intervals of the PT variable transformed logarithmically to ensure its normality, were far from the 80%-125% allowed for declaration of similarity. Conclusion: The test formulation Rivaroxaban Asarap? 20 mg, manufactured by Leti Laboratories, is interchangeable or bioequivalent in clinical and laboratory response to the reference formulation Xarelto? manufactured by Bayer Laboratories.
No takes yet. Share an insight, caveat, or question.
Roa et al. (2024) conducted an RCT in Healthy volunteers (n=25). Rivaroxaban (Laboratorios Leti) vs. Rivaroxaban (Bayer Laboratories) was evaluated on Prothrombin time (PT) on day 2 (95% CI 94.4-104, p=0.45). Rivaroxaban from Leti Laboratories demonstrated pharmacodynamic equivalence to the Bayer reference formulation, with logarithmically transformed prothrombin time ratios remaining within the required 80-125% range.