Key result
Repositioning embolized self-expandable THVs in the aorta yields ~73% long-term survival without device migration.
Why the study?
Long-term outcomes of patients experiencing self-expandable transcatheter heart valve embolization into the aorta during TAVI needed assessment.
What are the long-term outcomes and safety of repositioning self-expandable transcatheter heart valves embolized in the aorta during TAVI?
Observational (n=11)
No
What are the long-term outcomes and safety of repositioning self-expandable transcatheter heart valves embolized in the aorta during TAVI?
Answers are grounded in this paper and cite their sources.
Repositioning embolized self-expandable transcatheter heart valves in the aorta during TAVI appears to be a safe long-term management strategy, despite some leaflet degeneration.
This study assesses the long-term outcomes of patients who suffered from self-expandable transcatheter heart valve (THV) embolized in the aorta in transcatheter aortic valve implantation (TAVI).We retrospectively reviewed the patients with self-expandable THV embolized in the aorta. Follow-up computed tomography was performed to assess the THV migration, struct fractures, and device-related aortic complications.Of the 539 TAVI patients, 11 suffered from self-expandable THV embolized in the aorta. Two patients underwent open-heart surgery to remove the embolized THVs in the ascending aorta. Embolized THVs were repositioned in the aortic arch distal to the left subclavian artery (n = 3) and the thoracic descending aorta (n = 6). Three patients died during a median follow-up time of 40 months. The remaining eight survivors presented with New York Heart Association functional class I or II at the last follow-up. Degeneration of embolized prostheses with thick leaflets and rolled cusp edges was observed in three patients. There was no evidence of valve migration, strut fracture, prosthesis-associated aortic complication, and thrombosis attached on embolized valve for all patients with THVs repositioned in the aorta.Self-expandable THV embolization can be effectively managed in TAVI. Although some embolized valves exhibited leaflet degeneration, the long-term safety of repositioning embolized self-expandable THV in the aorta is assured.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2021) conducted an observational in Severe aortic stenosis or bioprosthetic valve failure with self-expandable THV embolized in the aorta (n=11). Repositioning of embolized self-expandable THV in the aorta was evaluated on Long-term clinical outcomes and device-related complications. Repositioning embolized self-expandable transcatheter heart valves in the aorta is a safe bail-out maneuver, with 8 of 11 patients surviving at a median 40-month follow-up without device migration.