Key result
Delayed cardiac CT scanning improves LAA thrombus detection accuracy over early scanning alone.
Why the study?
The diagnostic performance of 320-detector cardiac computed tomography for detecting left atrial appendage thrombi relative to transesophageal echocardiography had not yet been evaluated.
Does dual-phase snapshot 320-detector CCT accurately detect left atrial appendage thrombus compared to TEE in patients scheduled for pulmonary vein isolation?
Observational (n=91)
Blinded readers
No
Does dual-phase snapshot 320-detector CCT accurately detect left atrial appendage thrombus compared to TEE in patients scheduled for pulmonary vein isolation?
Absolute Event Rate: 0.99% vs 0.87%
p-value: p=<0.001
The addition of delayed scanning to early scanning on 320-detector CCT improves diagnostic performance for LAA thrombus detection and may obviate unnecessary TEE with minimal additional radiation exposure.
Delayed-phase 320-detector CCT may improve LAA thrombus detection; hypothesis-generating before any reduction in pre-PVI TEE use.
The diagnostic performance of 320-detector cardiac computed tomography (CCT) for the detection of thrombi in the left atrial appendage (LAA), relative to transesophageal echocardiography (TEE) as the gold standard, has not yet been evaluated. A total of 91 consecutive patients who were scheduled to undergo pulmonary vein isolation and underwent TEE and CCT were enrolled in this study. Delayed scanning on CCT was performed following early scanning, at 60 seconds after the start of the contrast injection. The radiation dose was estimated for both scans. The early scans showed a contrast medium filling defect (FD) in the LAA in 27 patients, whereas the delayed scans showed an FD in the LAA in six patients. Of these, five patients were confirmed to have a thrombus in the LAA by TEE. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 100, 74.4, 18.5, 100, and 75.8% for early scanning and 100, 98.8, 83.3, 100, and 98.9% for delayed scanning, respectively. The area under the curve for the detection of a thrombus in the LAA on the delayed scans was significantly larger than that for the detection on the early scans (0.99 versus 0.87, P < 0.001). The estimated median radiation doses for the early and delayed scans were 2.86 and 0.42 mSv, respectively. Addition of delayed scanning to early scanning improved the diagnostic performance for the detection of a thrombus in the LAA and may obviate unnecessary TEE, with minimal additional radiation exposure.
No takes yet. Share an insight, caveat, or question.
Kuronuma et al. (2019) conducted an observational in Atrial fibrillation (n=91). Delayed scanning in 320-detector cardiac computed tomography vs. Early scanning was evaluated on Area under the curve (AUC) for the detection of a thrombus in the left atrial appendage (p=<0.001). Delayed scanning in 320-detector cardiac computed tomography significantly improved the diagnostic accuracy for detecting left atrial appendage thrombi compared to early scanning alone (AUC 0.99 vs 0.87, P < 0.001).