Key result
3D-guided TAVR successfully treats severe AR in a quadricuspid valve, achieving a 2 mmHg mean gradient.
Why the study?
Performing TAVR in patients with high-risk quadricuspid aortic valve may be feasible, but uncertainties remain regarding procedural planning and outcome prediction.
Does patient-specific 3D printing and computational fluid dynamics simulation improve procedural planning and outcomes of transcatheter aortic valve replacement in a patient with quadricuspid aortic valve?
Case Report (n=1)
No
Does patient-specific 3D printing and computational fluid dynamics simulation improve procedural planning and outcomes of transcatheter aortic valve replacement in a patient with quadricuspid aortic valve?
Patient-specific 3D printing and computational fluid dynamics simulations are feasible and valuable tools for planning and predicting outcomes of TAVR in complex anatomies like quadricuspid aortic valve.
May aid TAVR planning in rare anatomies; leaves open whether modeling improves outcomes over standard approaches.
Background Performing transcatheter aortic valve replacement (TAVR) in patients with high-risk quadricuspid aortic valve (QAV) may be feasible, but uncertainties remain regarding the development of a comprehensive procedural plan and predicting the outcomes. Case summary We report a case of a 70-year-old patient with a high-risk (EuroSCORE II: 11.2%) QAV (type B) and severe aortic regurgitation (regurgitant jet area measuring 9.8 cm 2 ). To avoid high-risk surgery, we selected a 29-mm J-Valve for the transapical TAVR without the occurrence of paravalvular leak based on a patient-specific 3D printed model. Computational fluid dynamics simulations were performed to evaluate the hemodynamic parameters pre- and post-TAVR and showed that the trans-aortic valve pressure gradient decreased from 4.7 mmHg to 3.5 mmHg, the peak trans-aortic velocity decreased from 1.02 m/s to 0.89 m/s, and the low wall shear stress area was increased from 18.92 cm 2 to 19.15 cm 2 . These findings suggest the effectiveness of the TAVR procedure. Based on the simulation results, the procedure was successfully implemented, leading to an improvement in the patient's clinical status. Conclusion Three-dimensional printing and computational fluid dynamics simulations may be valuable tools for planning, assessing procedural outcomes, and evaluating risks in TAVR procedures for patients with QAV.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2025) conducted a case report in Quadricuspid aortic valve with severe aortic regurgitation (n=1). Transcatheter aortic valve replacement (TAVR) with 29-mm J-Valve was evaluated on Procedural success and hemodynamic improvement. TAVR guided by 3D printing and computational fluid dynamics successfully treated severe aortic regurgitation in a quadricuspid aortic valve, reducing the mean pressure gradient to 2 mmHg.