Key result
Higher power or longer duration radiofrequency energy increases lesion size in equine and swine myocardium.
Why the study?
Due to thicker myocardial walls and higher blood flow in horses, it was unknown whether conventional radiofrequency ablation settings used in humans can be extrapolated to horses.
Radiofrequency ablation lesion dimensions are dependent on power, duration, and species, indicating that settings used in human or swine models may need adjustment for the thicker equine myocardium to achieve transmurality.
Warrants species-specific ablation parameters in large-animal models; leaves open human translation and optimal transmural settings.
Radiofrequency ablation is a promising technique for arrhythmia treatment in horses. Due to the thicker myocardial wall and higher blood flow in horses, it is unknown if conventional radiofrequency settings used in human medicine can be extrapolated to horses. The study aim is to describe the effect of ablation settings on lesion dimensions in equine myocardium. To study species dependent effects, results were compared to swine myocardium. Right ventricular and right and left atrial equine myocardium and right ventricular swine myocardium were suspended in a bath with circulating isotonic saline at 37 °C. The ablation catheter delivered radiofrequency energy at different-power-duration combinations with a contact force of 20 g. Lesion depth and width were measured and lesion volume was calculated. Higher power or longer duration of radiofrequency energy delivery increased lesion size significantly in the equine atrial myocardium and in equine and swine ventricular myocardium (P < 0.001). Mean lesion depth in equine atrial myocardium ranged from 2.9 to 5.5 mm with a diameter ranging from 6.9 to 10.1 mm. Lesion diameter was significantly larger in equine tissue compared to swine tissue (P = 0.020). Obtained data in combination with estimated wall thickness can improve lesion transmurality which might reduce arrhythmia recurrence. Optimal ablation settings may differ between species.
No takes yet. Share an insight, caveat, or question.
Buschmann et al. (2024) studied In vitro myocardial tissue (n=21). Radiofrequency ablation vs. Different power-duration combinations and species (equine vs swine) was evaluated on Lesion size (depth, diameter, volume) (p=<0.001). Higher power or longer duration of radiofrequency energy delivery significantly increased lesion size in equine and swine myocardial tissue.