Answers are grounded in this paper and cite their sources.
OBJECTIVES: Magnetization-prepared rapid gradient-echo (MP-RAGE) sequences are routinely acquired for brain exams, providing high conspicuity for enhancing lesions. Vessels, however, also appear bright, which can complicate the detection of small lesions. T1RESS (T1 relaxation-enhanced steady-state) sequences have been proposed as an alternative to MP-RAGE, offering improved lesion conspicuity and suppression of blood vessels. This work aims to evaluate the performance of radial T1RESS variants for motion-robust contrast-enhanced brain MRI. MATERIALS AND METHODS: Radial stack-of-stars sampling was implemented for steady-state free-precession-based rapid T1RESS acquisition with saturation recovery preparation. Three variants were developed using a balanced steady-state free-precession readout (bT1RESS), an unbalanced fast imaging steady precession (FISP) readout (uT1RESS-FISP), and an unbalanced reversed FISP readout (uT1RESS-PSIF). Image contrast was evaluated in numerical simulations and phantom experiments. The motion robustness of radial T1RESS was demonstrated with a motion phantom. Four patients and six healthy volunteers were scanned at 3 T and 0.55 T. Extensions were developed combining T1RESS with GRASP for dynamic imaging, with GRAPPA for accelerated scans, and with Dixon for fat/water separation. RESULTS: In simulations and phantom scans, uT1RESS-FISP provided higher signal intensity for regions with lower T1 values (<500 ms) compared with MP-RAGE. In motion experiments, radial uT1RESS-FISP showed fewer artifacts than MP-RAGE and Cartesian uT1RESS-FISP. In patients, both unbalanced uT1RESS variants provided higher lesion conspicuity than MP-RAGE. Blood vessels appeared bright with MP-RAGE, gray with uT1RESS-FISP, and dark with uT1RESS-PSIF. At 0.55 T, bT1RESS provided high signal-to-noise ratio T1-weighted images without banding artifacts. Lastly, dynamic T1RESS images with a temporal resolution of 10.14 seconds/frame were generated using the GRASP algorithm. CONCLUSIONS: Radial T1RESS sequences offer improved lesion conspicuity and motion robustness and enable dynamic imaging for contrast-enhanced brain MRI. Both uT1RESS variants showed higher tumor-to-brain contrast than MP-RAGE and may find application as alternative techniques for imaging uncooperative patients with small brain lesions.
No takes yet. Share an insight, caveat, or question.
Zi et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: