Key result
Implementing extended cardiac views during fetal ultrasound increased examination time and incomplete studies without improving the detection rate of congenital heart disease.
Why the study?
The impact of extended cardiac views on examination time, repeat imaging, and anomaly detection following implementation of 76811 guidelines was unknown.
Does the addition of extended fetal cardiac ultrasound views improve the detection of congenital heart disease in singleton pregnancies?
Observational (n=624)
No
Does the addition of extended fetal cardiac ultrasound views improve the detection of congenital heart disease in singleton pregnancies?
Answers are grounded in this paper and cite their sources.
Implementing extended fetal cardiac ultrasound views increased examination time and the need for repeat imaging without improving the detection rate of congenital heart disease.
This study evaluates the impact of extended cardiac views on examination time, repeat imaging, and anomaly detection before and after implementation of 76811 guidelines (American Institute of Ultrasound in Medicine Consensus 2014). It is a retrospective study of singleton pregnancies undergoing detailed ultrasound imaging at 18 weeks' gestation or greater before and after the protocol change in an academic, tertiary care fetal center. Views required prior to 2014: 4-chamber, left outflow tract, right outflow tract. Additional views required after 2014: bicaval, aortic arch, 3-vessel, and 3-vessel trachea. Fetuses with known anomalies were excluded. Rates of detection of congenital heart disease (CHD), examination completion, repeat examination recommendation, fetal echocardiogram recommendation, completion by body mass index, and cardiac examination time were determined. Six hundred twenty-four subjects were included, 217 before and 407 after protocol change. Views obtained were as stated in the American Institute of Ultrasound in Medicine/Society for Maternal-Fetal Medicine consensus. Detection of CHD was not improved. Examination times increased by 20% (6.4 vs 7.7 minutes, P < 0.05). Number of incomplete studies increased by 130% (11% to 26%, P < 0.05). Twice as many patients were referred for repeat examination (6% vs 13%, P < 0.05). Completion rates were negatively correlated with body mass index. Recommendations for fetal echocardiogram were unchanged (5% vs 6%, P = 0.6). Additional imaging did not increase detection rate of CHD (3% vs 2%, P = 0.3). Extended cardiac views resulted in increased examination time, more incomplete examinations, and more repeat examinations without changing detection rates of CHD.
No takes yet. Share an insight, caveat, or question.
Fratto et al. (2018) conducted an observational in Singleton pregnancies (n=624). Extended cardiac views (post-2014 guidelines) vs. Standard cardiac views (pre-2014 guidelines) was evaluated on Detection of congenital heart disease (CHD) (p=0.3). Implementing extended cardiac views during fetal ultrasound increased examination time and incomplete studies without improving the detection rate of congenital heart disease.