Key result
Shifting from ventricular sensing to right ventricular pacing mode immediately impaired left ventricular diastolic function, significantly decreasing E'-wave velocity (P<=0.002) and E'/A' ratio (P<=0.001).
Why the study?
Does right ventricular apical pacing compared to intrinsic ventricular sensing affect left ventricular contractility and diastolic function in patients with sick sinus syndrome?
Does right ventricular apical pacing compared to intrinsic ventricular sensing affect left ventricular contractility and diastolic function in patients with sick sinus syndrome?
Right ventricular apical pacing immediately impairs left ventricular diastolic function while preserving contractility compared to intrinsic ventricular sensing in patients with sick sinus syndrome.
May warrant minimizing RV apical pacing to preserve diastolic function; leaves open randomized confirmation of clinical impact in sick sinus syndrome.
AIMS: The immediate effects of electric remodelling on the left ventricular (LV) function by dual-chamber pacemakers remain unknown. The purpose of our study was to assess the interaction between heart rates and right ventricular pacing (VP) on LV contractility and diastolic function. METHOD AND RESULTS: Twenty-five patients with dual-chamber pacemakers and sick sinus syndrome were evaluated. Echocardiographic examinations included standard and tissue-Doppler echocardiography at bilateral mitral annulus margins under either the intrinsic atrio-ventricular sequential conduction (ventricular sensing; VS) mode or right ventricular apical pacing (VP) mode. Under either mode, we accelerated the pacing rate at an increment of 15 b.p.m. step-by-step from 60 to 90/min. The tissue-Doppler echocardiography of mitral annulus showed that under the VS status, accelerating atrial pacing rate from 60 to 90 b.p.m. enhanced A'-wave velocity (P < or =0.002), whereas no significant change of LV ejection fraction (LVEF) and E'-wave velocity were noted. Under the VP status, acceleration of pacing rates exerted no effect on the LVEF, E'-, and A'-wave (P = NS). While shifting the pacemaker mode from VS to VP, the E'-wave velocity (P < or =0.002) and E'/A' ratio decreased significantly (P < or = 0.001). The A'-wave velocity also increased significantly during shifting to VP mode at 60 b.p.m. (P < or =0.004). CONCLUSION: At fixed pacing rates, shifting from VS to VP mode impaired LV diastolic function immediately with preserved LV contractility. The acceleration of heart rate impaired LV diastolic function under VS mode.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2009) studied Sick sinus syndrome (n=25). Right ventricular apical pacing (VP) mode vs. Ventricular sensing (VS) mode was evaluated on Left ventricular contractility and diastolic function (p=<=0.001). Shifting from ventricular sensing to right ventricular pacing mode immediately impaired left ventricular diastolic function, significantly decreasing E'-wave velocity (P<=0.002) and E'/A' ratio (P<=0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: