Key result
CT-derived GLS correlates moderately with TTE but systematically underestimates strain by ~6%.
Why the study?
The feasibility of CT-derived myocardial strain measurement in patients with advanced cardiac valve disease and how it compares to transthoracic echocardiography-derived strain needed to be explored.
Does CT-derived myocardial strain measurement correlate with TTE-derived strain in patients with advanced cardiac valve disease?
Observational (n=43)
No
Does CT-derived myocardial strain measurement correlate with TTE-derived strain in patients with advanced cardiac valve disease?
Effect estimate: r = 0.60
p-value: p=<0.001
CT-derived myocardial strain measurement is feasible and highly reproducible in patients with advanced valve disease, correlating moderately with echocardiography, though it systematically underestimates strain values.
CT GLS underestimates TTE values and should not substitute without calibration; leaves open its clinical role in valve disease pending validation.
To explore the feasibility of CT-derived myocardial strain measurement in patients with advanced cardiac valve disease and to compare it to strain measurements derived from transthoracic echocardiography (TTE). 43 consecutive patients with advanced cardiac valve disease and clinically indicated retrospectively gated cardiac CTs were retrospectively analyzed. The longitudinal, circumferential as well as radial systolic strain were determined in all patients utilizing a commercially available CT strain software. In 36/43 (84%) patients, CT-derived longitudinal strain was compared to speckle-tracking TTE. Pearson's correlation coefficients as well as Bland-Altman analysis were used to compare the CT-derived strain measurements to TTE. The intra- and inter-reader-reliability of the CT-derived strain measurements were assessed by intra-class correlation coefficients (ICCs). Strain measurements were feasible in all patients. CT-derived global longitudinal strain (GLS) correlated moderately with TTE-derived GLS (r = 0.6, p < 0.001). A moderate correlation between CT-derived GLS and CT-derived left ventricular ejection fraction was found (LVEF, r = - 0.66, p = 0.036). Bland-Altman analysis showed a systematic underestimation of myocardial strain by cardiac CT compared to TTE (mean difference: - 5.8%, 95% limit of agreement between - 13.3 and 1.8%). Strain measurements showed an excellent intra- and inter-reader-reliability with an intra-reader ICC of 1.0 and an inter-reader ICC of 0.99 for GLS measurements. CT-derived myocardial strain measurements are feasible in patients with advanced cardiac valve disease. They are highly reproducible and correlate with established parameters of strain measurements. Our results encourage the implementation of CT-derived strain measurement into clinical routine.
No takes yet. Share an insight, caveat, or question.
Vach et al. (2021) conducted an observational in Advanced cardiac valve disease (n=43). CT-derived myocardial strain measurement vs. Transthoracic echocardiography (TTE) was evaluated on Correlation between CT-derived and TTE-derived global longitudinal strain (r = 0.60, p=<0.001). CT-derived global longitudinal strain correlated moderately with TTE-derived strain (r = 0.60, p < 0.001) but systematically underestimated it by a mean difference of -5.8%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: