Key result
High-power short-duration ablation links to ~30% greater 12-month sinus rhythm maintenance vs low-power long-duration.
Why the study?
Multiple predictors of recurrence after atrial fibrillation ablation are established, but the impact of first-pass isolation on late outcomes comparing high-power short-duration to low-power long-duration ablation required evaluation.
Does high-power short-duration ablation improve first-pass isolation and reduce atrial fibrillation recurrence compared to low-power long-duration ablation in patients undergoing first AF ablation?
Observational (n=144)
Yes
Does high-power short-duration ablation improve first-pass isolation and reduce atrial fibrillation recurrence compared to low-power long-duration ablation in patients undergoing first AF ablation?
High-power short-duration ablation for atrial fibrillation achieves higher rates of first-pass isolation and better 12-month maintenance of sinus rhythm compared to conventional low-power long-duration ablation.
Answers are grounded in this paper and cite their sources.
May support high-power short-duration ablation for AF; leaves open confirmation in randomized trials before practice change.
Introduction: Different results are described after atrial fibrillation ablation and multiples predictors of recurrence are well established. Objective: Evaluate and analyze if first-pass isolation effect (FPI) during first atrial fibrillation (AF) ablation with high-power short-duration (HPSD) comparing to low-power long-duration (LPLD) can impact on late outcome. Methods: Observational, retrospective study, 144 patients submitted to HPSD and LPLD ablation. HPSD: 71 patients, 50 (70.42%) males, mean age 59.73 years, 52 (73.24%) hypertension, 44 (61.97%) obstructive apnea, 23 (32.39%) arterial disease, 20 (28.17%) diabetes, and 10(14.08%) stroke. CHADS2VASC2 2.57. CT: 73 patients, 50 (68.49%) males, mean age 60.7 years, 53 (72.60%) hypertension, 41 (56.16%) obstructive apnea, 28 (38.36%) arterial disease, 14 (19.17%) diabetes and 8 (10.96%) stroke. CHAD2SVASC2 2.22. Results: Recurrence occurred in 33 patients (22.92%) at 12 months follow-up, HPSD with 9 patients and LPLD with 24 patients. Higher rate of bilateral FPI were observed in HPSD patients with 62 of 71 patients comparing to 17 of 73 patients in LPLD (P < 0.00001). At the end of study 62 (87.32%) of 71 HPSD patients were in sinus rhythm comparing to 49 (67.12%) of 73 patients in LPLD (P 0.0039). Conclusion: HPSD ablation produced higher rates of FPI comparing to LPLD. HPSD compared to LPLD showed a superiority in maintaining sinus rhythm at 12 months. At patients submitted to HPSD protocol ablation, FPI could predict higher rate of sinus rhythm at 12 months follow-up.
No takes yet. Share an insight, caveat, or question.
Vassallo et al. (2020) conducted an observational in Atrial fibrillation (n=144). High-power short-duration (HPSD) ablation vs. Low-power long-duration (LPLD) ablation was evaluated on Maintenance of sinus rhythm at 12 months (p=0.0039). High-power short-duration ablation increased the maintenance of sinus rhythm at 12 months compared to low-power long-duration ablation.