Key result
LBBAP linked to a ~72% higher rate of acceptable pacing parameters versus HBP.
Why the study?
Increasing interest in physiological pacing has faced challenges like lead deployment and rising thresholds with His-bundle pacing, leading left bundle branch area pacing to emerge as an alternative approach.
Does left bundle branch area pacing (LBBAP) improve pacing parameters and reduce lead revisions compared to His-bundle pacing (HBP)?
Observational (n=100)
No
Does left bundle branch area pacing (LBBAP) improve pacing parameters and reduce lead revisions compared to His-bundle pacing (HBP)?
Answers are grounded in this paper and cite their sources.
During early adoption, left bundle branch area pacing (LBBAP) is associated with significantly better pacing parameters and fewer lead revisions compared to His-bundle pacing (HBP).
BACKGROUND: Increasing interest in physiological pacing has been countered with challenges such as accurate lead deployment and increasing pacing thresholds with His-bundle pacing (HBP). More recently, left bundle branch area pacing (LBBAP) has emerged as an alternative approach to physiologic pacing. OBJECTIVE: To compare procedural outcomes and pacing parameters at follow-up during initial adoption of HBP and LBBAP at a single center. METHODS: Retrospective review, from September 2016 to January 2020, identified the first 50 patients each who underwent successful HBP or LBBAP. Pacing parameters were then assessed at first follow-up after implantation and after approximately 1 year, evaluating for acceptable pacing parameters defined as sensing R-wave amplitude >5 mV, threshold <2.5 V @ 0.5 ms, and impedance between 400 and 1200 Ω. RESULTS: The HBP group was younger with lower ejection fraction compared to LBBAP (73.2 ± 15.3 vs. 78.2 ± 9.2 years, p = .047; 51.0 ± 15.9% vs. 57.0 ± 13.1%, p = .044). Post-procedural QRS widths were similarly narrow (119.8 ± 21.2 vs. 116.7 ± 15.2 ms; p = .443) in both groups. Significantly fewer patients with HBP met the outcome for acceptable pacing parameters at initial follow-up (56.0% vs. 96.4%, p = .001) and most recent follow-up (60.7% vs. 94.9%, p ≤ .001; at 399 ± 259 vs. 228 ± 124 days, p ≤ .001). More HBP patients required lead revision due to early battery depletion or concern for pacing failure (0% vs. 13.3%, at a mean of 664 days). CONCLUSION: During initial adoption, HBP is associated with a significantly higher frequency of unacceptable pacing parameters, energy consumption, and lead revisions compared with LBBAP.
No takes yet. Share an insight, caveat, or question.
Oates et al. (2021) conducted an observational in Patients requiring physiologic pacing (n=100). Left bundle branch area pacing (LBBAP) vs. His-bundle pacing (HBP) was evaluated on Acceptable pacing parameters (sensing R-wave amplitude >5 mV, threshold <2.5 V @ 0.5 ms, and impedance between 400 and 1200 Ω) at initial follow-up (p=0.001). Left bundle branch area pacing (LBBAP) yielded significantly more patients with acceptable pacing parameters at initial follow-up compared to His-bundle pacing (96.4% vs. 56.0%, p=0.001).