Key result
High premature ventricular complex burden (>0.145%/d) was significantly associated with an increased risk of cardiac events in heart failure patients (HR 2.028; 95% CI 1.418-2.901; P<0.001).
Why the study?
The clinical significance of premature ventricular complexes in heart failure remains unclear.
Does high PVC burden predict cardiac events in patients hospitalized for worsening heart failure?
Cohort (n=435)
Does high PVC burden predict cardiac events in patients hospitalized for worsening heart failure?
Effect estimate: HR 2.028 (95% CI 1.418-2.901)
p-value: p=<.001
A PVC burden >0.145%/d on pre-discharge Holter monitoring is an independent predictor of cardiac events in patients hospitalized for worsening heart failure.
May support post-discharge risk stratification in HF; leaves open whether PVC suppression alters outcomes.
Background The clinical significance of premature ventricular complexes (PVCs) in heart failure (HF) remains unclear. We aimed to clarify the associations of PVC burden with re‐hospitalization and cardiac death in HF patients. Methods We studied 435 HF patients (271 men, mean age 65 years). All patients were hospitalized for worsening HF. After optimal medications, echocardiography, 24 hours Holter monitoring and cardiopulmonary exercise testing were performed before discharge. The clinical characteristics and outcomes of the HF patients were investigated. Results During a median follow‐up period of 2.3 years, there were 125 (28.7%) cardiac events (re‐hospitalization due to worsening HF, fatal arrhythmias, or cardiac death). The patients with cardiac events had higher PVC burden compared to those without (median 0.374%/d [interquartile range 0.013‐1.510] vs median 0.026%/d [interquartile range 0.000‐0.534], P < .001). We examined cutoff value of PVC burden for predicting cardiac events. Receiver‐operating characteristic analysis showed PVC burden (>0.145%/d) to be a predictive factor of cardiac events (area under the curve: 0.64). Kaplan‐Meier analysis demonstrated that cardiac events were more frequent in patients with high‐PVC burden (>0.145%/d, n = 194) compared to those with low‐PVC burden (≤0.145%/d, n = 241). Furthermore, the high‐PVC burden patients had left ventricular (LV) and atrial dilatation, reduced LV ejection fraction, and impaired exercise capacity, compared to the low‐PVC burden patients. In Cox proportional hazards analysis, high‐PVC burden was significantly associated with cardiac events with a hazard ratio of 2.028 (95% confidence interval: 1.418‐2.901, P < .001). Conclusion These results suggest that PVC burden is an important predictor of cardiac events in HF patients.
No takes yet. Share an insight, caveat, or question.
Yamada et al. (2019) conducted a cohort in Heart failure (n=435). High PVC burden (>0.145%/d) vs. Low PVC burden (≤0.145%/d) was evaluated on Cardiac events (re-hospitalization due to worsening HF, fatal arrhythmias, or cardiac death) (HR 2.028, 95% CI 1.418-2.901, p=<.001). High premature ventricular complex burden (>0.145%/d) was significantly associated with an increased risk of cardiac events in heart failure patients (HR 2.028; 95% CI 1.418-2.901; P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: