Key result
Superb microvascular imaging demonstrated almost perfect interobserver reliability for measuring carotid intima-media thickness compared to B-mode ultrasonography.
Why the study?
The study was conducted to investigate interobserver reliability when measuring carotid intima-media thickness using superb microvascular imaging compared with B-mode ultrasonography.
Does superb microvascular imaging (SMI) improve interobserver reliability in measuring carotid intima-media thickness compared to B-mode ultrasonography?
Observational (n=20)
Blinded observers
No
Does superb microvascular imaging (SMI) improve interobserver reliability in measuring carotid intima-media thickness compared to B-mode ultrasonography?
Superb microvascular imaging (SMI) provides significantly higher interobserver reliability than standard B-mode ultrasonography for measuring carotid intima-media thickness.
Answers are grounded in this paper and cite their sources.
SMI may enhance carotid IMT measurement consistency; hypothesis-generating for clinical adoption pending prospective validation.
Objective The objective of this study was to investigate the interobserver reliability when measuring the carotid intima media thickness (IMT) using superb microvascular imaging (SMI) and B-mode ultrasonography. Methods Two sonologists were selected to scan the left common carotid artery and measure IMT first with B-mode and then with SMI on 20 patients. They were blinded to each other results. Intraclass correlation coefficients (ICCs) were calculated to estimate the inter-rater reliability using both the modes of scanning. Results Interobserver agreement when using SMI, for both near wall and far wall, was almost perfect (ICC, 0.870; 95% confidence interval [CI], 0.700–0.946). Interobserver agreement when using B-mode was poor for near wall (ICC, 0.396; 95% CI, −0.048–0.708) and moderate for far wall (ICC, 0.474, 95% CI, 0.070–0.749). Conclusions SMI proved to be a greatly reliable tool in the measurement of carotid IMT.
No takes yet. Share an insight, caveat, or question.
Hasan et al. (2018) conducted an observational in Carotid intima-media thickness measurement (n=20). Superb microvascular imaging (SMI) vs. B-mode ultrasonography was evaluated on Interobserver reliability (ICC) for carotid intima-media thickness (ICC 0.870, 95% CI 0.700-0.946). Superb microvascular imaging demonstrated almost perfect interobserver reliability for measuring carotid intima-media thickness compared to B-mode ultrasonography.