Key result
Non-invasive measurement of total-Hb + Mb using near-infrared spectroscopy significantly correlated with leg vessel conductance during sub-maximal dynamic exercise (r=0.792 to 0.980).
Why the study?
Does near-infrared spectroscopy (NIRS) accurately reflect muscle vasodilation during exercise in patients with and without cardiac dysfunction?
Observational (n=16)
Does near-infrared spectroscopy (NIRS) accurately reflect muscle vasodilation during exercise in patients with and without cardiac dysfunction?
NIRS provides a valid, non-invasive method to assess working muscle vasodilation during exercise in cardiac patients.
NIRS may support non-invasive assessment of muscle vasodilation during exercise in cardiac patients; leaves open prospective validation and clinical utility.
BACKGROUND: In patients with chronic heart failure, an inadequate increase in muscle blood flow resulting from impaired vasodilation plays a key role in their exercise intolerance. However, no non-invasive methods to assess muscle vasodilation during dynamic exercise were available. We investigated whether the changes in tissue hemoglobin and myoglobin content (total-Hb + Mb) determined by non-invasive measurement using near-infrared spectroscopy (NIRS) reflect vessel conductance of working muscle during exercise. METHODS AND RESULTS: Sixteen patients (10 patients with normal cardiac systolic function, 6 with cardiac dysfunction) performed incremental bicycle exercise testing. Total-Hb + Mb from the right vastus lateralis muscle was monitored using NIRS. Leg blood flow (LBF) in the right femoral vein was measured using a thermodilution technique every 30-60 s. Leg vessel conductance was calculated as LBF/mean arterial pressure at each time of the measurement. In all cases except 1, the levels of total-Hb + Mb showed significant correlation with the leg vessel conductance (r=0.792 to 0.980). Intra-subject reproducibility of the NIRS measurement was also confirmed in 6 patients. CONCLUSIONS: Total-Hb + Mb from NIRS reflected muscle vasodilation during sub-maximal dynamic exercise in patients with and without cardiac dysfunction, indicating that NIRS provides a valuable method to assess the working muscle vasodilation.
No takes yet. Share an insight, caveat, or question.
Watanabe et al. (2005) conducted an observational in Cardiac patients with and without cardiac dysfunction (n=16). Near-infrared spectroscopy (NIRS) vs. Thermodilution technique was evaluated on Correlation between total-Hb + Mb levels and leg vessel conductance (r=0.792 to 0.980). Non-invasive measurement of total-Hb + Mb using near-infrared spectroscopy significantly correlated with leg vessel conductance during sub-maximal dynamic exercise (r=0.792 to 0.980).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: