Key result
Transformer-based deep learning model using multi-point ECGs classifies HF status changes with ~87% accuracy.
Why the study?
Deep learning models have shown promise in detecting HF via ECG, but their utility for continuous HF monitoring and detecting status changes remains uncertain.
Does a Transformer-based deep learning model using multi-point ECGs accurately classify heart failure status changes in adult patients?
Observational (n=6,531)
No
Does a Transformer-based deep learning model using multi-point ECGs accurately classify heart failure status changes in adult patients?
Answers are grounded in this paper and cite their sources.
A deep learning model using multi-point 12-lead ECGs accurately detected changes in heart failure status, suggesting utility for non-invasive continuous monitoring.
Aims: Heart failure (HF) hospitalizations are associated with poor survival outcomes, emphasizing the need for early intervention. Deep learning algorithms have shown promise in HF detection through electrocardiogram (ECG). However, their utility in ongoing HF monitoring remains uncertain. This study developed a deep learning model using 12-lead ECGs collected at 2 different time points to evaluate HF status changes, aiming to enhance early intervention and continuous monitoring in various healthcare settings. Methods and results: We analysed 30 171 ECGs from 6531 adult patients at Kobe University Hospital. The participants were randomly assigned to training, validation, and test datasets. A Transformer-based model was developed to classify HF status into deteriorated, improved, and no-change classes based on ECG waveform signals at two different time points. Performance metrics, such as the area under the receiver operating characteristic curve (AUROC) and accuracy, were calculated, and attention mapping via gradient-weighted class activation mapping was utilized to interpret the model's decision-making ability. The patients had an average age of 64.6 years (±15.4 years) and brain natriuretic peptide of 66.3 pg/mL (24.6-175.1 pg/mL). For HF status classification, the model achieved an AUROC of 0.889 [95% confidence interval (CI): 0.879-0.898] and an accuracy of 0.871 (95% CI: 0.864-0.878). Conclusion: Transformer-based deep learning model demonstrated high accuracy in detecting HF status changes, highlighting its potential as a non-invasive, efficient tool for HF monitoring. The reliance of the model on ECGs reduces the need for invasive, costly diagnostics, aligning with clinical needs for accessible HF management. IRB Information: Kobe University Hospital Clinical & Translational Research Center (reference number: B220208).
No takes yet. Share an insight, caveat, or question.
Nishihara et al. (2025) conducted an observational in Heart failure (n=6,531). Transformer-based deep learning model using multi-point ECGs was evaluated on Classification of HF status into deteriorated, improved, and no-change classes (AUROC 0.889, 95% CI 0.879-0.898). A Transformer-based deep learning model using multi-point ECGs accurately classified heart failure status changes with an AUROC of 0.889 (95% CI 0.879-0.898) and an accuracy of 0.871.
Synapse has enriched 10 related papers. Consider them for comparative context: