Key result
CatBoost model using ECG and clinical data identifies ER acute heart failure with 0.90 AUROC.
Why the study?
Acute heart failure poses significant diagnostic challenges in the emergency room due to varied clinical presentation and limitations of traditional diagnostic methods.
Does a machine learning model using 12-lead ECG and clinical data accurately identify acute heart failure in emergency room patients?
Cohort (n=19,285)
Yes
Does a machine learning model using 12-lead ECG and clinical data accurately identify acute heart failure in emergency room patients?
A machine learning model using standard 12-lead ECGs and clinical data can accurately screen for acute heart failure in the emergency department.
May support ML screening for acute HF in the ED; hypothesis-generating and requires prospective validation.
AIMS: Acute heart failure (AHF) poses significant diagnostic challenges in the emergency room (ER) because of its varied clinical presentation and limitations of traditional diagnostic methods. This study aimed to develop and evaluate a deep learning model using electrocardiogram (ECG) data to enhance AHF identification in the ER. METHODS AND RESULTS: In this retrospective cohort study, we analysed the ECG data of 19 285 patients who visited ERs of three hospitals between 2016 and 2020; 9119 with available left ventricular ejection fraction and N-terminal prohormone of brain natriuretic peptide level data and who were diagnosed with AHF were included in the study. We extracted morphological and clinical parameters from ECG data to train and validate four machine learning models: baseline linear regression and more advanced models including XGBoost, Light GBM, and CatBoost. The CatBoost algorithm outperformed other models, showing superior area under the receiver operating characteristic and area under the precision-recall curve diagnostic accuracy across both internal (0.89 ± 0.01 and 0.89 ± 0.01) and external (0.90 and 0.89) validation data sets, respectively. The model demonstrated high accuracy, precision, recall, and f1 score, indicating robust performance in AHF identification. CONCLUSION: The developed machine learning model significantly enhanced AHF detection in the ER using conventional 12-lead ECGs combined with clinical data. These findings suggest that ECGs, a common tool in the ER, can effectively help screen for AHF.
No takes yet. Share an insight, caveat, or question.
Moon et al. (2025) conducted a cohort in Acute heart failure (n=19,285). CatBoost machine learning model using ECG and clinical data vs. Baseline linear regression, XGBoost, and Light GBM was evaluated on Diagnostic accuracy (AUROC and AUPRC) for acute heart failure (AUROC 0.90). A CatBoost machine learning model using ECG and clinical data accurately identified acute heart failure in the emergency room, achieving an external validation AUROC of 0.90.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: