Key result
Sympathetically driven pacing provided physiological heart rate modulations in AV block patients with chronotropic incompetence, yielding lower catecholamines during DDDR vs DDDC pacing (P<0.05).
Why the study?
Does a sympathetically driven pacemaker with a closed-loop sensor improve physiological heart rate modulation in patients with AV block and chronotropic incompetence?
Population
15 patients with AV block and a pacemaker controlled by a closed-loop system, including 8 patients with…
Comparison
Sympathetically driven pacemaker pacing with… vs Pacing with sensor activity Off.
Design
Cohort
Authors
Loading...
May lower catecholamines with closed-loop pacing in AV block; hypothesis-generating, needing RCTs before practice change.
Observational (n=15)
Does a sympathetically driven pacemaker with a closed-loop sensor improve physiological heart rate modulation in patients with AV block and chronotropic incompetence?
p-value: p=<0.05
A closed-loop autonomic nervous system-driven sensor provides physiological heart rate modulation and reduces catecholamine levels in patients with AV block and chronotropic incompetence.
Filho et al. (2000) conducted an observational in AV block (n=15). Sympathetically driven pacemaker (DDDR mode) vs. DDDC mode (sensor off) or normal sinus function was evaluated on Changes in heart rate and catecholamine levels during physiological maneuvers (p=<0.05). Sympathetically driven pacing provided physiological heart rate modulations in AV block patients with chronotropic incompetence, yielding lower catecholamines during DDDR vs DDDC pacing (P<0.05).