Key result
ANS-controlled stimulation rate using intracardiac impedance demonstrated excellent agreement with spontaneous sinus rhythm during exercise in patients with AV block.
Why the study?
Does rate responsive pacing using intracardiac impedance to determine sympathetic activity provide physiological rate adaptation in patients with AV block?
Does rate responsive pacing using intracardiac impedance to determine sympathetic activity provide physiological rate adaptation in patients with AV block?
Rate responsive pacing using intracardiac impedance to measure sympathetic activity provides physiological rate adaptation during exercise in patients with AV block.
Answers are grounded in this paper and cite their sources.
May support impedance-based rate response in AV block; hypothesis-generating and requires randomized outcome trials before practice change.
Modern pacemaker technology renders possible the adaptation of pacing rate to hemodynamic requirements. The most ambitious approach aims at restoration of the physiological closed-loop system by utilizing the information supplied by the autonomic nervous system (ANS) and extracted from myocardial contractile performance. Measurement is accomplished by the impedance method using the stimulation electrode as the measuring electrode. The ventricular inotropic parameter (VIP) has been identified as an ANS dependent parameter. A special detection algorithm, regional effective slope quantity (RQ), with high ANS sensitivity has been developed. Rate adaptation has been achieved by using an individually adjustable inotropic index (II). The concept has been evaluated in a multicenter study using a standardized exercise protocol. The results in patients with AV block demonstrate excellent agreement between spontaneous sinus rhythm and the ANS-controlled stimulation rate during different forms of exercise. Measurement of mean arterial blood pressure (MABP) supports the physiological approach of adapting the pacing rate to various types of hemodynamic challenges.
No takes yet. Share an insight, caveat, or question.
Schaldach et al. (1992) studied AV block. ANS-controlled stimulation rate using intracardiac impedance vs. Spontaneous sinus rhythm was evaluated on Agreement between spontaneous sinus rhythm and ANS-controlled stimulation rate during exercise. ANS-controlled stimulation rate using intracardiac impedance demonstrated excellent agreement with spontaneous sinus rhythm during exercise in patients with AV block.
Synapse has enriched 10 related papers. Consider them for comparative context: