Key result
CFD-derived vFFR shows potential to characterize iliac artery stenosis with a 77% area reduction.
Why the study?
Catheter-derived FFR is invasive, and non-invasive CFD-derived FFR (vFFR) commercially available for coronary arteries could potentially be applied to assess stenosis severity in other vessels such as the iliac arteries.
Can CFD-derived FFR (vFFR) accurately estimate pressure drop and stenosis severity in iliac artery stenosis?
Case Report (n=1)
Can CFD-derived FFR (vFFR) accurately estimate pressure drop and stenosis severity in iliac artery stenosis?
CFD-derived FFR (vFFR) demonstrates potential as a non-invasive method to characterize stenosis severity in iliac arteries, extending its application beyond coronary arteries.
Answers are grounded in this paper and cite their sources.
vFFR may non-invasively assess iliac stenosis severity; leaves open confirmation in larger cohorts.
Computational Fluid Dynamics (CFD) and time-resolved phase-contrast magnetic resonance imaging (PC-MRI) are potential non-invasive methods for the assessment of the severity of arterial stenoses. Fractional flow reserve (FFR) is the current "gold standard" for determining stenosis severity in the coronary arteries but is an invasive method requiring insertion of a pressure wire. CFD derived FFR (vFFR) is an alternative to traditional catheter derived FFR now available commercially for coronary artery assessment, however, it can potentially be applied to a wider range of vulnerable vessels such as the iliac arteries. In this study CFD simulations are used to assess the ability of vFFR in predicting the stenosis severity in a patient with a stenosis of 77% area reduction (>50% diameter reduction) in the right iliac artery. Variations of vFFR, overall pressure drop and flow split between the vessels were observed by using different boundary conditions. Correlations between boundary condition parameters and resulting flow variables are presented. The study concludes that vFFR has good potential to characterise iliac artery stenotic disease.
No takes yet. Share an insight, caveat, or question.
Skopalik et al. (2021) conducted a case report in Iliac artery stenosis (n=1). CFD derived FFR (vFFR) vs. In-vivo measurements was evaluated on Stenosis severity prediction (vFFR, overall pressure drop, and flow split). CFD-derived fractional flow reserve (vFFR) demonstrated good potential to characterize iliac artery stenotic disease in a patient with a 77% area reduction.