Key result
A multiscale closed-loop cardiovascular model was developed and its performance demonstrated in simulating neurogenic hypertension and acute 10% hemorrhage.
A novel multiscale closed-loop cardiovascular model can simulate autonomic responses to stressors like hemorrhage and hypertension.
Answers are grounded in this paper and cite their sources.
May support in silico testing of autonomic cardiovascular responses; leaves open clinical translation pending validation.
A computational tool is developed for simulating the dynamic response of the human cardiovascular system to various stressors and injuries. The tool couples 0-dimensional models of the heart, pulmonary vasculature, and peripheral vasculature to 1-dimensional models of the major systemic arteries. To simulate autonomic response, this multiscale circulatory model is integrated with a feedback model of the baroreflex, allowing control of heart rate, cardiac contractility, and peripheral impedance. The performance of the tool is demonstrated in 2 scenarios: neurogenic hypertension by sustained stimulation of the sympathetic nervous system and an acute 10% hemorrhage from the left femoral artery.
No takes yet. Share an insight, caveat, or question.
Canuto et al. (2018) studied Hemorrhage and hypertension (simulated). Multiscale closed-loop cardiovascular model was evaluated on Simulation of neurogenic hypertension and acute 10% hemorrhage. A multiscale closed-loop cardiovascular model was developed and its performance demonstrated in simulating neurogenic hypertension and acute 10% hemorrhage.