Key result
Mechanical mitral valve replacement was associated with larger exercise indexed effective orifice areas (1.57 vs 1.18 cm2/m2; P=0.0001) and improved 6-minute walk distance compared to bioprostheses.
Why the study?
Does biological mitral valve replacement compared to mechanical mitral valve replacement worsen exercise hemodynamics and functional capacity in patients with ischemic mitral regurgitation?
Cohort (n=86)
Does biological mitral valve replacement compared to mechanical mitral valve replacement worsen exercise hemodynamics and functional capacity in patients with ischemic mitral regurgitation?
Absolute Event Rate: 1.57% vs 1.18%
p-value: p=0.0001
In patients with ischemic mitral regurgitation undergoing CABG, mechanical mitral valve prostheses provide superior exercise hemodynamics and functional capacity compared to biological prostheses.
Mechanical MVR may improve exercise capacity in ischemic MR; hypothesis-generating, needs randomized confirmation before practice change.
Background In patients with ischemic mitral regurgitation requiring mitral valve replacement (MVR), the choice of the prosthesis type is crucial. The exercise hemodynamic and functional capacity performance in patients with contemporary prostheses have never been investigated. To compare exercise hemodynamic and functional capacity between biological (MVRb) and mechanical (MVRm) prostheses. Methods and Results We analyzed 86 consecutive patients with ischemic mitral regurgitation who underwent MVRb (n=41) or MVRm (n=45) and coronary artery bypass grafting. All patients underwent preoperative resting echocardiography and 6-minute walking test. At follow-up, exercise stress echocardiography was performed, and the 6-minute walking test was repeated. Resting and exercise indexed effective orifice areas of MVRm were larger when compared with MVRb (resting: 1.30±0.2 versus 1.19±0.3 cm 2 /m 2 ; P =0.03; exercise: 1.57±0.2 versus 1.18±0.3 cm 2 /m 2 ; P =0.0001). The MVRm had lower exercise systolic pulmonary arterial pressure at follow-up compared with MVRb (41±5 versus 59±7 mm Hg; P =0.0001). Six-minute walking test distance was improved in the MVRm (pre-operative: 242±43, post-operative: 290±50 m; P =0.001), whereas it remained similar in the MVRb (pre-operative: 250±40, post-operative: 220±44 m; P =0.13). In multivariable analysis, type of prosthesis, exercise indexed effective orifice area, and systolic pulmonary arterial pressure were joint predictors of change in 6-minute walking test (ie, difference between baseline and follow-up). Conclusions In patients with ischemic mitral regurgitation, bioprostheses are associated with worse hemodynamic performance and reduced functional capacity, when compared with MVRm. Randomized studies with longer follow-up including quality of life and survival data are required to confirm these results.
No takes yet. Share an insight, caveat, or question.
Fino et al. (2018) conducted a cohort in Ischemic mitral regurgitation (n=86). Mechanical mitral valve replacement (MVRm) vs. Biological mitral valve replacement (MVRb) was evaluated on Exercise indexed effective orifice area (cm2/m2) (p=0.0001). Mechanical mitral valve replacement was associated with larger exercise indexed effective orifice areas (1.57 vs 1.18 cm2/m2; P=0.0001) and improved 6-minute walk distance compared to bioprostheses.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: