Key result
Perioperative CIED management requires assessing device type, electromagnetic interference, and appropriate reprogramming or magnet use.
Why the study?
Increasing use of CIEDs and operating room electromagnetic interference risks require anesthesiologists to understand device types, programming, and magnet responses for safe perioperative care.
This review outlines essential perioperative management strategies for patients with CIEDs to prevent adverse events caused by electromagnetic interference during surgery.
Supports tailored CIED perioperative planning; leaves open prospective validation of standardized algorithms.
The use of cardiac implantable electronic devices (CIEDs) has increased significantly in recent years. Consequently, more patients with CIEDs will undergo surgery during their lifetime, and thus the involvement of anesthesiologists in the perioperative management of CIEDs is increasing. With ongoing advancements in technology, many types of CIEDs have been developed, including permanent pacemakers, leadless pacemakers, implantable cardioverter defibrillators, cardiac resynchronization therapy-pacemakers/defibrillators, and implantable loop recorders. The functioning of CIEDs exposed to an electromagnetic field can be affected by electromagnetic interference, potential sources of which can be found in the operating room. Thus, to prevent potential adverse events caused by electromagnetic interference in the operating room, anesthesiologists must have knowledge of CIEDs and be able to identify each type. This review focuses on the perioperative management of patients with CIEDs, including indications for CIED implantation to determine the baseline cardiovascular status of patients; concerns associated with CIEDs before and during surgery; perioperative management of CIEDs, including magnet application and device reprogramming; and additional perioperative provisions for patients with CIEDs. As issues such as variations in programming capabilities and responses to magnet application according to device can be challenging, this review provides essential information for the safe perioperative management of patients with CIEDs.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2024) conducted a review in Patients with cardiac implantable electronic devices (CIEDs) undergoing surgery. Perioperative management of CIEDs was evaluated. Perioperative management of patients with cardiac implantable electronic devices requires careful assessment of device type, potential electromagnetic interference, and appropriate reprogramming or magnet application.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: