Key result
PCG-derived systolic time intervals predict optimal AV delays with ~1% reduction in pump function.
Why the study?
Phonocardiography can determine systolic time intervals, but their relations with hemodynamics during atrioventricular delay optimization of biventricular pacing required investigation.
Do PCG-derived systolic time intervals accurately predict optimal AV delays compared to invasive hemodynamic measurements in patients undergoing CRT?
Do PCG-derived systolic time intervals accurately predict optimal AV delays compared to invasive hemodynamic measurements in patients undergoing CRT?
PCG-derived systolic time intervals provide a non-invasive method for AV delay optimization in CRT that closely approximates invasive hemodynamic measurements with minimal loss of pump function.
Answers are grounded in this paper and cite their sources.
PCG-based AV optimization may noninvasively approximate hemodynamics in CRT with minimal pump function loss; hypothesis-generating and requires prospective trials.
BackgroundPhonocardiography (PCG) can be used to determine systolic time intervals (STIs) from ventricular pacing spike to the first heart sound (VS1) and from the first to the second heart sound (S1S2).ObjectiveThe purpose of this study was to investigate the relations between STIs and hemodynamics during atrioventricular (AV) delay optimization of biventricular pacing (BiVP) in animals and patients.MethodsFive pigs with AV block underwent BiVP, while PCG was collected from an epicardial accelerometer. In 21 patients undergoing cardiac resynchronization therapy device implantation, PCG was recorded with a pulse generator–embedded microphone. Optimal AV delays derived from shortest VS1 and longest S1S2 were compared with AV delays derived from highest left ventricular pressure (LVP), maximal rate of rise in LVP, and stroke work.ResultsIn pigs, VS1 and S1S2 predicted the AV delays with optimal hemodynamics (highest LVP, maximal rate of rise in LVP, and stroke work) by a median error of 2–28 ms, resulting in a median loss of <2% of pump function. In patients, VS1 and S1S2 predicted the optimal AV delay by errors of 32.5 and 37.5 ms, respectively, resulting in 0.2%–0.9% lower LVP and stroke work, which were reduced to 21 and 24 ms in 8 patients with a full-capture AV delay of >180 ms.ConclusionDuring BiVP with varying AV delays, close relations exist between PCG-derived STIs and hemodynamic parameters. AV delays advised by PCG-derived STIs cause only a minimal loss of pump function compared with those based on invasive hemodynamic measurements.Trial RegistrationClinicalTrials.gov Identifier: NCT01832493 Phonocardiography (PCG) can be used to determine systolic time intervals (STIs) from ventricular pacing spike to the first heart sound (VS1) and from the first to the second heart sound (S1S2). The purpose of this study was to investigate the relations between STIs and hemodynamics during atrioventricular (AV) delay optimization of biventricular pacing (BiVP) in animals and patients. Five pigs with AV block underwent BiVP, while PCG was collected from an epicardial accelerometer. In 21 patients undergoing cardiac resynchronization therapy device implantation, PCG was recorded with a pulse generator–embedded microphone. Optimal AV delays derived from shortest VS1 and longest S1S2 were compared with AV delays derived from highest left ventricular pressure (LVP), maximal rate of rise in LVP, and stroke work. In pigs, VS1 and S1S2 predicted the AV delays with optimal hemodynamics (highest LVP, maximal rate of rise in LVP, and stroke work) by a median error of 2–28 ms, resulting in a median loss of <2% of pump function. In patients, VS1 and S1S2 predicted the optimal AV delay by errors of 32.5 and 37.5 ms, respectively, resulting in 0.2%–0.9% lower LVP and stroke work, which were reduced to 21 and 24 ms in 8 patients with a full-capture AV delay of >180 ms. During BiVP with varying AV delays, close relations exist between PCG-derived STIs and hemodynamic parameters. AV delays advised by PCG-derived STIs cause only a minimal loss of pump function compared with those based on invasive hemodynamic measurements.
No takes yet. Share an insight, caveat, or question.
Luo et al. (2022) studied Patients undergoing cardiac resynchronization therapy (n=21). Atrioventricular delay optimization using PCG-derived systolic time intervals vs. Invasive hemodynamic measurements (LVP and stroke work) was evaluated on Optimal AV delay prediction error and loss of pump function. Atrioventricular delay optimization using PCG-derived systolic time intervals predicted optimal AV delays with errors of 32.5-37.5 ms in patients, resulting in 0.2%-0.9% lower pump function.
Synapse has enriched 10 related papers. Consider them for comparative context: