Key result
MyDiagnostick beats manual pulse checks for AF screening with 100% sensitivity.
Why the study?
MyDiagnostick has been validated for AF screening in Caucasian primary care populations, but validation was needed in a multi-ethnic Asian population in the community setting.
Does the MyDiagnostick tool accurately identify atrial fibrillation compared to manual pulse check in a multi-ethnic Asian community population?
Cross-Sectional (n=671)
Does the MyDiagnostick tool accurately identify atrial fibrillation compared to manual pulse check in a multi-ethnic Asian community population?
The MyDiagnostick tool is highly sensitive and specific for atrial fibrillation screening in a multi-ethnic Asian community setting, outperforming manual pulse check in sensitivity.
Answers are grounded in this paper and cite their sources.
May support MyDiagnostick over pulse check for AF screening in Asian cohorts; hypothesis-generating pending prospective validation.
Introduction: MyDiagnostick is an atrial fibrillation (AF) screening tool that has been validated in the Caucasian population in the primary care setting. Methods: In our study, we compared MyDiagnostick with manual pulse check for AF screening in the community setting. Results: In our cohort of 671 candidates from a multi-ethnic Asian population, AF prevalence was found to be 1.78%. Of 12 candidates, 6 (50.0%) had a previous history of AF and another 6 (50.0%) were newly diagnosed with AF. Candidates found to have AF during the screening were older (72.0 ± 11.7 years vs. 56.0 ± 13.0 years, P < 0.0001) and had a higher CHADSVASC risk score (2.9 ± 1.5 vs. 1.5 ± 1.1, P = 0.0001). MyDiagnostick had a sensitivity of 100.0% and a specificity of 96.2%. In comparison, manual pulse check had a sensitivity of 83.3% and a specificity of 98.9%. Conclusion: MyDiagnostick is a simple AF screening device that can be reliably used by non-specialist professionals in the community setting. Its sensitivity and specificity are comparable and validated across various studies performed in different population cohorts.
No takes yet. Share an insight, caveat, or question.
Yeo et al. (2022) conducted a cross-sectional in Atrial fibrillation (n=671). MyDiagnostick vs. Manual pulse check was evaluated on Sensitivity for atrial fibrillation screening. MyDiagnostick for atrial fibrillation screening demonstrated a sensitivity of 100.0% and specificity of 96.2%, compared to 83.3% and 98.9% for manual pulse check in a multi-ethnic Asian cohort.
Synapse has enriched 10 related papers. Consider them for comparative context: