Key result
3D echocardiography demonstrates ~87% concordance with CMR for grading TR severity, outperforming 2D echocardiography.
Why the study?
Routine 2DE often disagrees with CMR in classifying TR severity, and the incremental value of 3DE remains unknown due in part to the lack of a generalizable grading scheme across modalities.
Does 3-dimensional echocardiography improve the accuracy of tricuspid regurgitation severity grading compared to 2-dimensional echocardiography in patients with symptomatic TR?
Observational (n=144)
Yes
Does 3-dimensional echocardiography improve the accuracy of tricuspid regurgitation severity grading compared to 2-dimensional echocardiography in patients with symptomatic TR?
Answers are grounded in this paper and cite their sources.
3D echocardiography provides a more accurate assessment of tricuspid regurgitation severity than 2D echocardiography, showing substantial agreement with cardiac magnetic resonance imaging.
BACKGROUND: Tricuspid regurgitation (TR) is associated with increased mortality and is often underdiagnosed due to limitations in imaging modalities. While routine 2-dimensional echocardiography (2DE) demonstrates frequent disagreement with cardiac magnetic resonance imaging (CMR) in classifying TR severity, the incremental value of 3-dimensional echocardiography (3DE) remains unknown also due to the lack of a generalizable grading scheme across imaging modalities. Therefore, this study provides an intermodality comparison of all 3 imaging modalities (2DE, 3DE, and CMR) in evaluating TR severity and proposes an adapted 5-class grading scheme for TR severity using CMR. METHODS: A total of 144 patients with symptomatic TR were analyzed across 2 cohorts: a derivation cohort (n=91) from the University Hospital of Munich and a validation cohort (n=53) from the Heart Center Leipzig. All patients underwent multimodality imaging, including transthoracic 2DE, transesophageal 3DE, and CMR. The adapted 5-class CMR-based grading scheme was proposed and externally validated. RESULTS: In the derivation cohort (median age 81 years, 66% female), TR severity grading by 3DE highly correlated with CMR (87% concordance within a 1-grade difference), significantly outperforming 2DE (68% concordance). While 3DE underestimated right ventricular dimensions compared with CMR ( P <0.001), it provided a comparable measure of TR severity and right ventricular function. 2DE achieved the lowest accuracy rates compared with CMR (34.5%; P =0.005) with frequent overestimation of TR severity. An overestimation of TR severity by 3DE compared with CMR was significantly less frequent than with 2DE (21% versus 56%; P <0.001). Cohen κ analysis confirmed a substantial and superior agreement between 3DE and CMR compared with 2DE (κ=0.63 versus 0.41; P =0.01). The results were externally validated, showing comparable results within the derivation and validation cohorts. CONCLUSIONS: 3DE provides an accurate assessment of TR severity comparable to CMR. The proposed 5-class grading scheme for TR severity using CMR demonstrates high accuracy and external validity.
No takes yet. Share an insight, caveat, or question.
Doldi et al. (2025) conducted an observational in Symptomatic tricuspid regurgitation (n=144). 3-dimensional echocardiography (3DE) vs. 2-dimensional echocardiography (2DE) was evaluated on Concordance of TR severity grading with CMR within a 1-grade difference (Cohen κ 0.63 vs 0.41, p=0.01). 3-dimensional echocardiography demonstrated superior agreement with CMR for grading tricuspid regurgitation severity compared to 2-dimensional echocardiography.