PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 24, 2022Critical Care138 citationsOpen Access

Venous return and mean systemic filling pressure: physiology and clinical applications

RPRomain PersichiniCLChristopher LaiJTJean–Louis Teboul

Key Result

Guyton's physiological model of venous return provides a framework for understanding the hemodynamic effects of fluid therapy, norepinephrine, and prone positioning in critically ill patients.

PICO

P
Population
Circulatory failure

Limitations

  • The heart-lung interactions method might be affected by the time delay between the arterial pulse pressure measurement and the venous return flow.
  • Any error in the measurement of CVP may introduce a large error in the estimation of the curve slope and in Pmsf.
  • The transient stop-flow arm method might be limited by the fact that the venous compartment is less compliant in the muscle than in the splanchnic vascular bed.

Abstract

Venous return is the flow of blood from the systemic venous network towards the right heart. At steady state, venous return equals cardiac output, as the venous and arterial systems operate in series. However, unlike the arterial one, the venous network is a capacitive system with a high compliance. It includes a part of unstressed blood, which is a reservoir that can be recruited via sympathetic endogenous or exogenous stimulation. Guyton's model describes the three determinants of venous return: the mean systemic filling pressure, the right atrial pressure and the resistance to venous return. Recently, new methods have been developed to explore such determinants at the bedside. In this narrative review, after a reminder about Guyton's model and current methods used to investigate it, we emphasize how Guyton's physiology helps understand the effects on cardiac output of common treatments used in critically ill patients.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Persichini et al. (2022) conducted a review in Circulatory failure. Guyton's physiological model of venous return provides a framework for understanding the hemodynamic effects of fluid therapy, norepinephrine, and prone positioning in critically ill patients.

synapsesocial.com/papers/6a1510176383cb718e9ae093https://doi.org/10.1186/s13054-022-04024-x
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Venous Return at Various Right Atrial Pressures and the Normal Venous Return Curve1957 · 552 citations
  2. 2A comparison of cardiovascular effects of dobutamine and isoprenaline after open heart surgery.1976 · 41 citations
  3. 3Right atrial pressure and venous return during cardiopulmonary bypass2017 · 56 citations
  4. 4Estimating mean circulatory filling pressure in clinical practice: a systematic review comparing three bedside methods in the critically ill2018 · 84 citations
  5. 5Hemodynamic Response to Norepinephrine with and without Inhibition of Nitric Oxide Synthase in Porcine Endotoxemia1999 · 51 citations